Efficacy and safety of a parylene-coated occluder for atrial septal defect: a prospective, multi-cen

来源 :中华医学杂志英文版 | 被引量 : 0次 | 上传用户:h563268898
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background::Nitinol-containing devices are widely used in clinical practice. However, there are concerns about nickel release after nitinol-containing device implantation. This study aimed to compare the efficacy and safety of a parylene-coated occluder n vs. a traditional nitinol-containing device for atrial septal defect (ASD).n Methods::One-hundred-and-eight patients with ASD were prospectively enrolled and randomly assigned to either the trial group to receive a parylene-coated occluder (n n = 54) or the control group to receive a traditional occluder (n n = 54). The plugging success rate at 6 months after device implantation and the pre- and post-implantation serum nickel levels were compared between the two groups. A non-inferiority design was used to prove that the therapeutic effect of the parylene-coated device was non-inferior to that of the traditional device. The Cochran-Mantel-Haenszel chi-squared test with adjustment for central effects was used for the comparison between groups.n Results::At 6 months after implantation, successful ASD closure was achieved in 52 of 53 patients (98.11%) in both the trial and control groups (95% confidence interval (CI): [-4.90, 5.16]) based on per-protocol set analysis. The absolute value of the lower limit of the 95% CI was 4.90%, which was less than the specified non-inferiority margin of 8%. No deaths or severe complications occurred during 6 months of follow-up. The serum nickel levels were significantly increased at 2 weeks and reached the maximum value at 1 month after implantation in the control group (n P 0.05).n Conclusions::The efficacy of a parylene-coated ASD occluder is non-inferior to that of a traditional uncoated ASD occluder. The parylene-coated occluder prevents nickel release after device implantation and may be an alternative for ASD, especially in patients with a nickel allergy.“,”Background::Nitinol-containing devices are widely used in clinical practice. However, there are concerns about nickel release after nitinol-containing device implantation. This study aimed to compare the efficacy and safety of a parylene-coated occluder n vs. a traditional nitinol-containing device for atrial septal defect (ASD).n Methods::One-hundred-and-eight patients with ASD were prospectively enrolled and randomly assigned to either the trial group to receive a parylene-coated occluder (n n = 54) or the control group to receive a traditional occluder (n n = 54). The plugging success rate at 6 months after device implantation and the pre- and post-implantation serum nickel levels were compared between the two groups. A non-inferiority design was used to prove that the therapeutic effect of the parylene-coated device was non-inferior to that of the traditional device. The Cochran-Mantel-Haenszel chi-squared test with adjustment for central effects was used for the comparison between groups.n Results::At 6 months after implantation, successful ASD closure was achieved in 52 of 53 patients (98.11%) in both the trial and control groups (95% confidence interval (CI): [-4.90, 5.16]) based on per-protocol set analysis. The absolute value of the lower limit of the 95% CI was 4.90%, which was less than the specified non-inferiority margin of 8%. No deaths or severe complications occurred during 6 months of follow-up. The serum nickel levels were significantly increased at 2 weeks and reached the maximum value at 1 month after implantation in the control group (n P 0.05).n Conclusions::The efficacy of a parylene-coated ASD occluder is non-inferior to that of a traditional uncoated ASD occluder. The parylene-coated occluder prevents nickel release after device implantation and may be an alternative for ASD, especially in patients with a nickel allergy.
其他文献
期刊
期刊
期刊
期刊
期刊
期刊
期刊
期刊
期刊
Background::Intravenous thrombolysis (IVT) is an effective way for treating acute ischemic stroke (AIS). However, its effects have not been established among AIS patients with unclear stroke symptoms or with stroke onset for >4.5 h.Methods::We searched Pu