论文部分内容阅读
目的探讨迈尔集成内镜洗消中心清洗消毒消化内镜的效果。方法随机抽样迈尔集成内镜洗消中心清洗消毒后的消化内镜56件作为研究组,采用手工清洗消毒四槽法清洗消毒后的消化内镜50件作为对照组,分别进行生物学监测。结果研究组内壁消毒合格率为100%,对照组为92%,两组差异有统计学意义(P<0.05);两组外壁消毒合格率均为100%。结论迈尔集成内镜洗消中心清洗消毒的应用,提高了消化内镜的清洗消毒质量。
Objective To explore the effect of cleaning, disinfecting and digestion endoscopy in Meyer integrated endoscope decontamination center. Methods Fifty-five patients with digestive endoscopes cleaned and disinfected by Meyer integrated endoscope decontamination center were randomly selected as the research group. Fifty pieces of digestive endoscopes cleaned and disinfected by manual cleaning and disinfecting four-slot method were used as the control group to conduct biological monitoring separately. Results The pass rate of disinfection on the inner wall of the study group was 100% and that of the control group was 92%. The difference between the two groups was statistically significant (P <0.05). Conclusions Mayer integrated endoscope decontamination center cleaning and disinfection applications, improve the quality of digestive endoscopy cleaning and disinfection.