脊柱金属内固定术后IDEAL与频率选择脂肪抑制FSE图像质量对比

来源 :临床放射学杂志 | 被引量 : 0次 | 上传用户:wkan
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的比较IDEAL序列和FS-FSE序列对减轻脊柱金属内固定相关伪影面积大小、脂肪抑制均匀性、椎管内结构的显示能力。方法选取脊柱金属内固定术后行脊柱MRI检查的患者40例,所有受检者脊柱内固定均为含量89%的钛六铝四钒(美敦力枢法模)。分别选取矢状位和轴位IDEAL-T_2WI、FS-FSE-T_2WI正中层面图像对金属伪影面积进行测量分析。脂肪抑制效果评价和椎管内结构显示效果评价均采用3分法。图像噪声评价测量脊髓ROI和背景ROI区域的信号强度与标准差,计算信噪比和对比度噪声比。结果累及3个腰椎椎弓板总的金属伪影面积在矢状位和轴位IDEAL-T_2WI和FS-FSE-T_2WI上分别为(2168±1454)mm~2、(4278±1259)mm2(P<0.003)和(1327±321)mm~2、(2777±1185)mm~2(P<0.001);IDEAL-T_2WI和FS-FSE-T_2WI的脂肪抑制评分观察者1和观察者2分别为1.83±0.39、0.60±0.81(P<0.05)和1.90±0.30、0.48±0.60(P<0.05);IDEAL-T_2WI和FSFSE-T_2WI的椎管内结构显示评分观察者1和观察者2分别为1.25±0.78、0.65±0.89(P<0.05)和1.40±0.67、0.60±0.78(P<0.05);图像噪声SNR和CNR在IDEAL-T_2WI和FS-FSE-T_2WI分别为97.13±33.55、42.11±12.53(P<0.05)和38.52±21.05、46.52±17.44(P>0.05)。结论相较于FS-FSE,IDEAL能显著减轻脊柱内固定金属相关伪影,提供更加均匀的脂肪抑制图像,提高椎管内和周围软组织结构的显示效果。 Objective To compare the performance of IDEAL and FS-FSE sequences in reducing the size of the artifact-related area of ​​spinal metal internal fixation, the uniformity of fat suppression, and the structure of the spinal canal. Methods Forty patients with spine MRI after spine metal internal fixation were selected. All patients underwent spinal internal fixation with Titanium-hexa-tetra-vanadium (Medtronic model) with 89% content. The sagittal and axial IDEAL-T_2WI and FS-FSE-T_2WI median images were selected to measure the metal artifact area respectively. Evaluation of fat suppression and spinal structure showed that the results were evaluated using 3 points. Image Noise Assessment Signal strength and standard deviation of the spinal ROI and background ROI region were measured and the ratio of signal to noise and contrast noise was calculated. Results The total metal artifacts involved in the three lumbar discs were (2168 ± 1454) mm2, (4278 ± 1259) mm2 (P <0.003) and (1327 ± 321) mm ~ 2, (2777 ± 1185) mm ~ 2, respectively (P <0.001). The fat suppression scores of IDEAL-T 2 WI and FS-FSE-T 2 WI were 1.83 ± 0.39,0.60 ± 0.81 (P <0.05) and 1.90 ± 0.30,0.48 ± 0.60 (P <0.05). The spinal canal structures of IDEAL-T_2WI and FSFSE-T_2WI showed that the scores of observer 1 and observer 2 were 1.25 ± The SNR and CNR of image noise were 97.13 ± 33.55 and 42.11 ± 12.53 (P <0.05) in IDEAL-T 2WI and FS-FSE-T 2WI groups, P <0.05, 0.78,0.65 ± 0.89 and 1.40 ± 0.67,0.60 ± 0.78 <0.05) and 38.52 ± 21.05, 46.52 ± 17.44 (P> 0.05). Conclusion Compared with FS-FSE, IDEAL can significantly reduce the fixation-related artifacts in the spine, provide a more uniform fat-suppressed image, and improve the visualization of soft tissue structures in and around the spinal canal.
其他文献
ue*M#’#dkB4##8#”专利申请号:00109“7公开号:1278062申请日:00.06.23公开日:00.12.27申请人地址:(100084川C京市海淀区清华园申请人:清华大学发明人:隋森芳文摘:本发明属于生物技
从高等级公路桥梁桥面防水的必要性入手,介绍了高分子聚合物防水涂料的性能要求及施工方法.
【正】 一、荷兰农业发展概况荷兰国土面积4.2万平方公里,总人口1549万。人口密度为375人/平方公里,比我国高两倍,是全球人口最稠密的国家之一。荷兰人均耕地1.3亩,一半以上
烟台市是全国久负盛名的水果产区,全市水果栽培面积23.3万hm^2,总产量达300万t。主栽树种苹果,面积达13.3万hm^2,产量250万t,占水果总产量的83.3%。但近几年来,苹果的价格一直不稳,下跌
通过N-甲基吗啉-N-氧化物(NMMO)溶液(水质量分数20%)对木浆原纤维预处理结合高速搅拌制备微纳米纤维素(MNC),并利用两种打浆度(未打浆15°SR和45°SR)的漂白针叶木浆分别与所
ue*M#’#dkB4##8#”专利申请号:00109“7公开号:1278062申请日:00.06.23公开日:00.12.27申请人地址:(100084川C京市海淀区清华园申请人:清华大学发明人:隋森芳文摘:本发明属于生物技
会议
1 多媒体地理教学的特点运用多媒体进行地理教学,可以把多种教学方法,如直观教学、启发式教学、愉快教学和视听强化教学等紧密结合起来,从而达到启发学生主动思考,开发学生智
期刊
ue*M#’#dkB4##8#”专利申请号:00109“7公开号:1278062申请日:00.06.23公开日:00.12.27申请人地址:(100084川C京市海淀区清华园申请人:清华大学发明人:隋森芳文摘:本发明属于生物技
目的研究老年退行性腰椎管狭窄症不同手术方式的选择及疗效对比。方法选取我院2012—11-2014—2间诊治的老年退行性腰椎管狭窄患者70例,根据患者意愿将其分为对照组和观察组,每