Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:tubage1022
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Computer-assisted procedures have recently been introduced for navigated femoral neck screw placement.Currently there is little information available regarding accuracy and efficiency of the different navigated procedures.The aim of this study was to compare two fluoroscopic navigation tracking technologies,a novel bi-planar robot navigation and standardized optoelectronic navigation,versus standard freehand fluoroscopic insertion in a Synbone hip model.Methods Eighteen fixed Synbone hip models were divided into 3 groups.C-arm navigated cannulated screws (AO-ASIF,diameter 7.3 mm) were inserted using freehand targeting (control group).A novel bi-planar robot system (TINAV,GD2000) and an optoelectronic system (Stryker OTS Navigation System) were used for the navigated procedures (robot group and optoelectronic group).Accuracy was measured using radiographic evaluation including the measurement of screw parallelism and decentralization,and joint penetration.To evaluate the efficiency,the number of guidewire passes,operative time and fluoroscopic images taken were noted.Results The two computer-assisted systems provided significantly improved accuracy compared to the freehand technique.Each of the parameters,including guidewire passes and number of fluoroscopy images,was significantly lower when using the computer-assisted systems than for freehand-unguided insertion (P <0.05),but operative time was significantly shorter when using freehand-unguided insertion than for the computer-assisted systems (P <0.05).Accuracy,operative time and number of fluoroscopy images taken were similar among the two navigated groups (P >0.05),but guidewire passes in the robot group were significantly less than in the optoelectronic group (P <0.05).Conclusions Both bi-planar robot navigation and optoelectronic navigation were similarly accurate and have the potential to improve accuracy and reduce radiation for freehand fluoroscopic targeting for insertion of cannulated screws in femoral neck fractures.Guidewire passes in the robot group were significantly less than in the optoelectronic group.However,both navigated procedures were associated with time-consuming registration and high rates of failed matching procedures.
其他文献
期刊
通过双因素分析法得出水玻璃激发矿渣制备灌浆料的最优参数,研究了多种化学缓凝剂单掺及复掺对碱激发矿渣灌浆料凝结时间和强度的影响。结果表明:BaCl2、Zn (NO3)2及其与葡萄糖酸
第六讲拆卸和装配(3)6.7 轴与毂连接的拆卸轴与轴上轮毂件(如齿轮、蜗轮、链轮、皮带轮、联轴器等)的连接是通过轴、孔之间的配合实现的,通常还同时使用了键连接.轴与毂连接
期刊
目的探讨妊娠期糖代谢异常孕妇孕期血糖控制满意后,新生儿早期动态血糖变化,进一步完善妊娠期糖代谢异常的系统管理方法,避免新生儿低血糖的发生。方法将120例妊娠期糖代谢异
目的 探讨干扰串珠素表达对椎板切除术后硬膜外瘢痕成纤维细胞中Ⅰ型胶原蛋白生成的影响. 方法 选取30 只2个月龄的SD雄性大鼠,行后路L4-5腰椎全椎板切除术.术后第20天取每只大鼠硬膜后方的瘢痕组织,采用组织块贴壁法进行细胞培养.筛选第3代瘢痕组织培养的成纤维细胞分为3组(n=6):慢病毒介导小发夹RNA(shRNA)干扰组[进行慢病毒介导shRNA干扰串珠素表达实验]、纯慢病毒无shRNA组和
北京东四环编组站立交桥跨越北京东郊铁路编组站 ,其主桥上部结构为 3跨连续钢箱 -钢筋混凝土叠合梁 ,全长共1 6 4m (45 m +74m +4 5 m ) ,其钢箱梁断面为 U形变截面 ,梁宽 3
1机立窑水泥存在和发展的依据rn1.1机立窑水泥在我国水泥工业发展中的重要地位rn机立窑水泥在我国水泥工业发展史上做出了重要贡献.它有力地支撑了我国国民经济的持续高速发
黄褐斑(melasma)是一种获得性面部色素沉着的皮肤病.临床多见于中青年女性,少数男性也有惟患.一般无自觉症状,主要影响患者容貌,并伴随不同程度的心烦易怒、月经失调、失眠等
HRB400钢筋是在低合金C-Mn钢基础上,加入适量合金元素,通过细晶强化和沉淀强化作用,在保证其塑性和焊接性能的基础上,提高其强度,达到国际上普遍使用的400MPa级钢筋的强度要