生产实际中,厚度0.5~1.5 mm的30CrMnSiA冷轧板lamb探伤存在杂波问题。通过检验各项性能和用扫锚电镜检测金相组织等,对30CrMnSiA薄规格冷轧板探伤杂波原因进行了分析。研究发现:钢板在临界变形量范围内,经再结晶退火后晶粒异常长大,是产生探伤杂波的主要原因;通过两段高温(970℃+920℃)正火处理,可消除晶粒不均缺陷,且lamb探伤杂波消失。
Production practice, the thickness of 0.5 ~ 1.5 mm 30CrMnSiA cold-rolled lamb plate testing there is a clutter problem. By testing the performance and scanning electron microscopy microstructure, etc., thin cold rolled plate 30CrMnSiA detection of clutter causes were analyzed. The results show that the main cause of flaw detection is the abnormal growth of the grain after the recrystallization annealing within the range of the critical deformation of the steel plate. After two stages of high temperature (970 ° C + 920 ° C) normalizing, the grain can be eliminated Uneven defects, and lamb detection noise disappears.