大型集装箱检查系统中 ,采用一维线阵列探测器并行扫描方式 ,并以直线加速器为 X射线源。其中多个探测器及前放的线性不一致性和非线性以及 X射线扇型束流的强度角分布导致图像出现水平条纹和明暗条带。这些因素严重影响了图像质量 ,必须对图像进行校正。通过实验 ,对探测器响应进行多点定标 ,再进行对数插值 ,得到校正参数。原始图像数据与校正参数进行适当的运算 ,图像即得到校正。计算结果与实验结果基本吻合 ,图像经校正后 ,水平条纹和条带基本消失。这种校正方法在集装箱检查系统中是有效和可行的 ,已经得到应用
Large container inspection system, using one-dimensional line array detector parallel scan mode, and the linear accelerator for the X-ray source. The linear incoordination and non-linearity of multiple detectors and preamplifiers and the angular distribution of the intensity of X-ray fan beam lead to horizontal stripes and light and dark bands in the image. These factors seriously affect the image quality and the image must be corrected. Through experiments, the detector response to multi-point calibration, then logarithmic interpolation, calibration parameters. The original image data and the correction parameters are properly calculated and the image is corrected. The calculated results are in good agreement with the experimental results. After the images are corrected, the horizontal stripes and strips basically disappear. This method of calibration is valid and feasible in container inspection systems and has been applied