论文部分内容阅读
根据熔融碳酸盐燃料电池 (MCFC)的数学模型 ,为了在温度允许界限内保持 MCFC电堆对外电压输出的恒定 ,采用自适应模糊控制理论对 MCFC电堆的控制进行研究 ,设计了一种具有两个自适应调整模块 (参数调整模块和聚类分析模块 )的模糊控制器 .仿真结果表明自适应模糊控制方法在性能和效果上都比 PID控制有明显的提高 ,从而能够保证 MCFC电堆在运行过程中的可靠性
According to the mathematical model of molten carbonate fuel cell (MCFC), in order to keep the output voltage of MCFC stack constant within the allowable temperature range, the adaptive fuzzy control theory is used to study the control of MCFC stack. Two adaptive adjustment modules (parameter adjustment module and cluster analysis module) fuzzy controller.The simulation results show that the adaptive fuzzy control method in the performance and effectiveness than the PID control has significantly improved, which can ensure the MCFC stack in the Reliability during operation