目的应急人员在处置放射事故过程中虽然有一定的防护,但都会受到不同程度的放射线照射,为了准确估算所受照的当量剂量。方法采用热释光剂量探测器敷贴在模拟人体各部位上,通过对剂量测定来估算这次应急处置过程中应急人员所受的当量剂量。结果全身所受放射线照射的当量剂量为121.75μSv,远低于年有效剂量值(20 mSv)。结论对该类事故的应急处置,操作规程是可行的,施行的防护是有效的,特别在近距离操作时间控制上达到应急要求,为应急人员减少所受的当量剂量起决定作用,针对放射事故发生原因提出防护对策。
The purpose of emergency personnel in the process of disposal of radiation accidents although there is a certain degree of protection, but will be subject to different levels of radiation exposure, in order to accurately estimate the equivalent dose received. Methods A thermoluminescence dose detector was applied to simulate various parts of the human body to estimate the equivalent dose of emergency personnel during the emergency treatment by measuring the dose. Results The whole body was irradiated with an equivalent dose of 121.75μSv, far below the annual effective dose (20 mSv). Conclusions Emergency treatment and operation procedures for such accidents are feasible and the protective measures applied are effective. In particular, they meet the emergency requirements on the control of close-range operation time and play a decisive role in reducing the equivalent dose received by emergency personnel. For radiation accidents The reasons for the proposed protection measures.