作者应用~(99m)TC-MIBI对121例乳腺肿物患者进行了显像观察,其中乳腺癌70例,良性肿瘤51例。结果灵敏度为91.4%,特异性68.6%,诊断符合率81.8%,假阳性率31.4%,假阴性率8.6%。与其它乳腺影像检查(近红外扫描、B超、乳腺钼靶片)相比较,诊断的符合率数值近似。作者认为该检查法对乳腺肿物的诊断有一定的价值。与其它的诊断方法联合互补,将会提高乳腺癌诊断率。但对浆细胞性乳腺炎显像率高,不能进行鉴别。
The authors applied ~(99m)TC-MIBI to observe 121 cases of breast tumors, including 70 cases of breast cancer and 51 cases of benign tumors. Results The sensitivity was 91.4%, specificity was 68.6%, diagnostic coincidence rate was 81.8%, false positive rate was 31.4%, and false negative rate was 8.6%. Compared with other breast imaging examinations (near-infrared scans, B-ultrasound, and mammography), the diagnostic coincidence rate is approximated. The author believes that the inspection method has a certain value for the diagnosis of breast tumors. Complementation with other diagnostic methods will increase the diagnostic rate of breast cancer. However, the imaging rate of plasma cell mastitis is high and cannot be identified.