论文部分内容阅读
我国化肥行业用的H22型氢氮气压缩机上有30多个环状气阀,目前因气阀失效而成为压缩机的突出问题。 为解决这个问题,我厂进行了气阀失效原因分析和使用寿命的统计,发现有很多气阀还能使用就被更换了,究其原因主要是: 1.升程限制器上的阀片导向块径向大量磨损,使阀片与导向块间间隙由0.2mm左右变成了1mm~2mm(见图1),这样阀
China’s fertilizer industry H22 hydrogen nitrogen compressor with more than 30 ring valve, the current valve failure due to become a prominent problem of the compressor. In order to solve this problem, our factory has carried on the valve failure analysis and service life statistics, found that there are many valves can be used to be replaced, the reason is mainly: 1. Lifter limiter valve-oriented Block a large number of radial wear, the valve plate and the gap between the guide block by 0.2mm into a 1mm ~ 2mm (see Figure 1), so that the valve