采用数值模拟与实验测量相结合的方法,完成了探测系统刻度,得到了该探测器对单能光子的能量全响应函数,在此基础上探索出改进的剥谱法,对测量得到的连续硬X射线能谱进行解析,扣除了测量谱中非光电效应对每道计数的贡献,复现了测量位置处的实际能谱,并对该能谱测量方法进行了误差分析,提出了进一步完善措施。
Using the method of numerical simulation and experimental measurement, the calibration of the detection system was completed, and the full energy response of the detector to uni-photons was obtained. Based on this, an improved stripping method was developed to measure the continuous hard X-ray spectra were analyzed, the contribution of non-photoelectric effect in each measurement of the spectrum was deducted, the actual energy spectrum at the measurement location was reproduced, and the error analysis of the energy spectrum measurement method was carried out, and further measures were put forward .