论文部分内容阅读
建立了格列喹酮血药浓度的测定方法。该法使用SpherisorbC18色谱柱,以乙腈-水(6535)为流动相,流速为1.0ml/min,检测波长为310nm,灵敏度为0.001AUFS。线性范围为50~2000ng/ml,方法回收率为95%以上,日内、日间误差小于7.0%。
The determination of gliquidone concentration was established. The method uses SpherisorbC18 column with acetonitrile-water (6535) as the mobile phase at a flow rate of 1.0 ml / min with a detection wavelength of 310 nm and a sensitivity of 0.001 AUFS. Linear range of 50 ~ 2000ng / ml, the method recovery rate of 95%, day, daytime error of less than 7.0%.