采用低毒性的溶剂甲苯取代有致癌性和高毒性的苯,通过HP-5毛细管色谱柱、ECD检测器气相色谱法测定水样中的苦味酸氯化后的氯化苦的量,进一步来确定苦味酸的浓度。采用保留时间定性,外标法定量。实验结果表明,该方法能快速有效地提取并测定水中的苦味酸,检出限低(0.15μg/L)、精密度(RSD=0.43%)和准确度高(加标回收率=96.6%)、工作曲线的线性(r=0.9991)较好。
Determination of chloropicrin chlorinated bitterness in water by gas chromatography with HP-5 capillary column and ECD detector using low-toxicity solvent toluene instead of carcinogenic and highly toxic benzene to further determine Picric acid concentration. Qualitative retention time, external standard method. The experimental results show that the method can rapidly and effectively extract and determine picric acid in water with low detection limit (0.15μg / L), precision (RSD = 0.43%) and high accuracy (standard addition recovery = 96.6%) , The working curve of the linear (r = 0.9991) is better.