一、概况大庆石油管理局第一采油厂北1—2联合站的压气机房,于87~88年先后安装了五台4L-40/0.3~3.5型石油气体压缩机.安装以后,在开机使用时,有严重的振动和噪声,且使用时间愈长,振动和噪声也愈加剧.实测最大噪声值(发生金属敲击声)达105dB,最低也有96dB.压缩机机体本身及和它所联接的管道系统振动严重,既影响;压缩机的使用寿命,也使安装在管道上的测温和测压仪表很快损毁.为了减少振动以延长机器和仪表的寿命,降低噪声以改善现场操作人员的劳动卫生条件,厂方
I. Overview Compressor room at the North 1-2 Joint Station of the First Oil Production Plant of Daqing Petroleum Administration has installed 5 sets of 4L-40 / 0.3 ~ 3.5 petroleum gas compressors from 1987 to 1988, and after installation, When there is severe vibration and noise, and the longer the use of time, the more the vibration and noise are more severe.Measured the maximum noise value (metal knocking sound) up to 105dB, the lowest is 96dB. Compressor body itself and the associated with it Serious vibrations in the piping system can affect both the life of the compressor and the temperature and pressure gauges mounted on the pipe. In order to reduce vibrations to extend the life of the machine and instrumentation and to reduce noise to improve on-site operator Labor and hygiene conditions, the factory