化学法测定硅铁中的铝,繁琐费时,不适应生产的需要。采用ICP-AES测定后,30min即可报出结果,准确可靠,满足了生产的需要。 1 仪器与工作条件、主要试剂 美国珀金—埃默尔公司P 2000型等离子体发射光谱仪 正向功率1.000kW,冷却气流量15L·min~(-1),辅助气流量1.0L·min~(-1),载气流量1.0L·min~(-1),蠕动泵进样速度1ml·min~(-1),观察高度15min,波长396.152nm。 铝标准溶液:1mg·ml~(-1),称取纯铝1.000g,用4mol.L~(-1)盐酸100ml溶解,转移至1L量瓶中,用水稀释至刻度、混匀。使用时配成100μg·ml~(-1)标准工作液。 2 分析方法
Chemical determination of ferrosilicon in silicon, cumbersome and time-consuming, not suited to production needs. Using ICP-AES determination, 30min can report the results, accurate and reliable, to meet the production needs. 1 instruments and working conditions, the main reagent PerkinElmer - US company P 2000 plasma emission spectrometer forward power 1.000kW, cooling gas flow 15L · min -1, the auxiliary gas flow 1.0L · min ~ ( -1), 1.0L · min -1 of carrier gas flow rate, 1ml · min -1 of peristaltic pump injection rate, 15min observation height and 396.152nm wavelength. Aluminum standard solution: 1mg · ml -1, weighed pure aluminum 1.000g, with 4mol.L ~ (-1) hydrochloric acid 100ml dissolved, transferred to 1L volumetric flask, diluted with water to the mark, and mix. When used with 100μg · ml ~ (-1) standard working solution. 2 analytical methods