通过回弹法分别测定结构块体和砂浆强度,进而根据相关公式计算了其弹性模量,并对计算结果进行了分析,指出弹性模量作为砌体结构古建筑有限元数值分析中最基本的力学参数,提供了一种对其实测的方法。
Through the rebound method, the strength of the block and the mortar were respectively measured, and then the elastic modulus was calculated according to the correlation formula. The calculation results were also analyzed. It is pointed out that the elastic modulus is the most basic value in the finite element numerical analysis of ancient buildings with masonry structure Mechanical parameters provide a way to actually measure it.