目的掌握湘潭市医疗机构X射线诊断机房防护水平,保护放射工作人员及公众的放射安全与身体健康。方法依据《医用X射线诊断放射防护要求》GBZ130-2013的要求,对X射线诊断机房进行屏蔽设施情况现场调查及防护检测。结果 2015年度调查的88家医疗机构防护总合格率为85.2%;检测的168间X射线诊断机房防护检测总合格率为92.3%。结论湘潭市当前更新和淘汰老旧的X射线诊断机和机房门,才是提高放射防护正当化、最优化的重中之重。
Objective To grasp the level of protection of X-ray diagnosis room in medical institutions in Xiangtan City, and to protect the radiation safety and physical health of radiation workers and the general public. Methods Based on the requirements of GBZ130-2013, “Radiation Protection Requirements of Medical X-Ray Diagnostics”, on-site investigation and protective testing of shielding facilities in X-ray diagnostic equipment room were conducted. Results The overall qualification rate of 88 medical institutions in 2015 was 85.2%. The total qualified rate of 168 X-ray diagnosis room examination was 92.3%. Conclusion Xiangtan City, the current update and out of the old X-ray diagnostic machine and machine room door, is to enhance the legitimacy of radiation protection, the most important priority.