论文部分内容阅读
文章分析了国电太原第一热电厂六期300MW机组再热器出口气温低的原因,通过对原锅炉设计煤种及再热器的系统指标分析,结合该炉的原始运行资料及运行参数,提出了解决问题的改造方案。
The paper analyzes the reason of the low outlet temperature of the reheater of the 6th phase 300MW unit of the first phase of the Power Plant in the Taiyuan Power Plant. By analyzing the system indexes of the original boiler design coal and reheater, combining with the original operation data and operating parameters of the furnace, Resolve the problem of the program.