论文部分内容阅读
本文介绍一台十道脉冲时间分析器.其道宽变化为1,1/2,1/4和1/8徽秒,道宽均匀度<±1.5%,道宽飘移与道宽之比对于1微秒档所测得的结果<±1/80,对于1/4微秒档所测得的结果<±1/67.选道部分采用了延迟线-符合-甄别系统.记录系统采用了十进位计数管.运转周期可以为常数,亦可为杂乱分布.该仪器适用于短寿命同位素衰减周期的测量和脉冲辐射源波形的测量,在装成后约半年的测试和使用中尚未发现不正常的现象.
This article describes a ten pulse time analyzer whose channel width changes to 1, 1/2, 1/4, and 1/8 emblem seconds, and the track width uniformity is <± 1.5%. The ratio of track width to track width 1 microsecond file measured results <± 1/80, for the 1/4 microsecond file measured results <± 1 / 67. Selected part of the use of the delay line - coincidence - screening system. The recording system used Decimal counter tube. The operating cycle can be constant, but also for clutter distribution. The instrument is suitable for short-lived isotope decay cycle measurement and pulse radiation source waveform measurement, installed in about six months after the test and use has not been found normal phenomenon.