[期刊论文] 作者:GAO Fei,NI Ning,HOU Jin-bing,SONG Ming-zhe,, 来源:Annual Report of China Institute of Atomic Energy 年份:2015
In 2015,Radiation Metrology Division of China Institute of Atomic Energy organized an environmental monitoring of nuclear radiation measuring intercomparison,an...
[期刊论文] 作者:XU Yang,GAO Fei,SONG Ming-zhe,NI Ning,, 来源:Annual Report of China Institute of Atomic Energy 年份:2016
Monte Carlo method was used to simulate the primary spectrum of filtered X-ray reference radiation,and described the uniformity and scattered radiation of this...
[期刊论文] 作者:GAO Fei,NI Ning,WANG Hong-yu,HOU Jin-bing,SONG Ming-zhe,, 来源:Annual Report of China Institute of Atomic Energy 年份:2014
Reference radiation filed produced by isotope source is necessary for metrological verification of radiation dose meter,with advantages of stability,single ray...
[期刊论文] 作者:GAO Fei,WANG Hong-yu,NI Ning,ZHANG Li,HOU Jin-bing,SONG Ming-zhe,, 来源:Annual Report of China Institute of Atomic Energy 年份:2012
Reference radiation filed produced by isotope source is necessary for calibration of radiation dose meter. 60Co single source radiation facility is an important...
[期刊论文] 作者:SONG Ming-zhe,WEI Ke-xin,HOU Jin-bing,WANG Hong-yu,GAO Fei,NI Ning,, 来源:Annual Report of China Institute of Atomic Energy 年份:2015
The Bragg-Gray cavity theory(B-G theory)provided a theoretical basis for the analytical calculation of the energy response for ionization chamber.It was widely...
[期刊论文] 作者:GAO Fei,NI Ning,XIAO Xue-fu,HOU Jin-bing,SONG Ming-zhe,WANG Hong-yu,, 来源:Annual Report of China Institute of Atomic Energy 年份:2014
Radiation metrology division of China Institute of Atomic Energy was entrusted by the Environmental Radiation Monitoring Technical Center of Environmental Prote...
[期刊论文] 作者:SONG Ming-zhe,YE Hong-sheng,WANG Hong-yu,GAO Fei,HOU Jin-bing,NI Ning,, 来源:Annual Report of China Institute of Atomic Energy 年份:2014
Quantity value transfer standard device for absorbed dose to water in high energy photon beam is mainly used for the standard and working chamber dosimeter cali...
[期刊论文] 作者:GAO Fei,XIAO Xue-fu,NI Ning,ZHANG Xi,HOU Jin-bing,SONG Ming-zhe,WANG Hong-yu,, 来源:Annual Report of China Institute of Atomic Energy 年份:2013
In order to study cosmic rays response characteristics of self-designed HPIC(high pressure ionization chamber),model JLZ-Ⅲ,the JLZ-Ⅲwas placed on a boat which...
[期刊论文] 作者:NI Ning,ZHANG Wei-hua,XIAO Xue-fu,GAO Fei,SONG Ming-zhe,HOU Jin-bing,WANG Hong-yu,, 来源:Annual Report of China Institute of Atomic Energy 年份:2015
Tissue equivalent proportional counter(TEPC)can differentiate the dose equivalent contributed from neutron and gamma ray in a mixture field and measure absorb d...
[期刊论文] 作者:SONG Ming-zhe,YE Hong-sheng,LI Wei,WEI Ke-xin,WANG Hong-yu,GAO Fei,HOU Jin-bing,, 来源:Annual Report of China Institute of Atomic Energy 年份:2013
Planar matrices of diodes or ionization chambers were widely used in the verification of dose for intensity modulated radiation therapy(IMRT)and tomotherapy.The...
[会议论文] 作者:ZHANG Zi-zhu,张紫竹,SONG Ming-zhe,宋明哲,LI Wei,李玮,CHEN Jun,陈军,YANG Yong,杨勇,LI Yi-guo,李义国, 来源:第八届(2012)北京核学会核应用技术学术交流会 年份:2012
医院中子照射器建成后,对分析室内及其屏蔽门外的γ剂量率和中子剂量当量率进行了测量,测量结果显示:分析室内局部γ剂量率与设计值相差较大,分析室屏蔽门外γ剂量率超过原设计监督区限值7.5 μSv/h,因此需对分析室内部及其屏蔽门进行屏蔽改造.根据蒙特卡罗程序......