Research on brachytherapy dose distributionverificationusing two-dimensional ionization chamber arra

来源 :2015北京首届国际近距离治疗肿瘤学术大会暨2015北京首届国际放射肿瘤学术论坛 | 被引量 : 0次 | 上传用户:smallAppleA
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective: To investigate the two-dimensional ionization chamber array Matrixx's feasibility of brachytherapy plan verification, seeking to establish a set of feasible brachytherapy dose distribution verification method.Methods: using well-type chamber to verify the source activity of Ir192;using the radioactive source to complete the calibration of GafChromic film model EBT3 through the Valencia skin applicator and SP34 water equivalent solid phantom, gets dose gray curve, find the percentage depth dose (PDD) curves under Valencia skin applicator and use it to help calibrating the Germany IBA company's two-dimensional ionization chamber array Matrixx, get a calibration factor Kuser.Using Freiburg Flap applicator and inserting the needle combine with solid water to build a phantom, after CT scans,complete the catheter reconstruction and dose distribution calibration in the oncentra treatment planning system, using the measurement and analysis software of OmniProl'mRT, the planned dose distribution and measurement dose distributions were compared.Results: the Ir192 dose distribution under Valencia skin applicator is of similar to accelerator beam, transverse and longitudinal symmetry is 0.17% and 0.16% respectively, the PDD of maximum dose is at 3mm under the applicator surface, PDD46.5% is at 11.6mm under the applicator surface.The measured dose distribution and TPS calculated dose plane is compared using gamma analysis method (3mm/3%), the ratio of pixels withinγ ≤ 1 is 97.67%, absolute dose measurement and calculation of dose deviation remains in 5%.Conclusion: the use of radiation field with a flattening filter Valencia applicator can be a source of radiation for trimming, trimmed uniform radiation field for dose calculation and measurement, can be directly used for calibration verification tool, to avoid the high dose gradient near the source due to dose error caused by position error, greatly reduced the energy response of the verification tool.Matrixxenvlution as brachytherapy dose distribution verification tool has good repeatability, avoiding the cost loss using film validation, is more rapid, convenient one of brachytherapy dosimetry QA verification tool.
其他文献
  背景 探讨血液透析患者的疲倦水平及其影响因素,为改善血液透析患者的疲倦程度,提高生活质量提供参考依据.方法 对我院维持性血液透析3个月以上的患者进行疲倦量表的问卷调
会议
会议
会议
CKD
  目的 探讨综合护理对慢性肾功能衰竭患者不良情绪和生活质量的影响.方法 选取2013年1月~2014年12月间我院收治的90例慢性肾功能衰竭患者作为研究对象,采用随机数字表法将
会议
  Objective To evaluate the impact of rheumatoid arthritis (RA) on work capacity and identify factors related to work capacity impairment in patients with RA.
会议