New Time Resolution Measurement Method

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:wilee818
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:To Time-of-Flight positron emission tomography(TOF-PET),the TOF benefit highly depends on the system timing precision.As a result,it is meaningful to measure the time resolution of the PET system.However,there is not any standard procedure for the measurement.In the article,we used the standard NEMA NECR and NEMA sensitivity coincidence data to analyze the PET system time resolution.Methods:The NECR measurement has many scatter events during the PET scanning.It is difficult to distinguish the real events and the scatters events.It is hard to evaluate the scatter events as well.Therefore,we proposed to use the coincidence data acquired from standard NEMA sensitivity measurement procedure.We used at least 10000 trues per slice collected from the sensitivity data acquired by the PET system.It is hard to ignore the statistics error on each Line-of-Response(LOR).It is necessary to merge the data of all five data sets acquired with different size absorbers.In practice,Inaccurate positioning of the line source in the center of PET FOV may lead to imprecise time resolution result.In order to compensate the time difference caused by misplacing,we introduced a source alignment procedure,which takes the advantage of the rigid line source.ResultsBy using the proposed method,we can get a global time resolution measurement.Conclusions:It is shown that,by using the sensitivity data acquired by standard NEMA procedure,we can get a measurement of the time resolution of the PET system.
其他文献
Purpose:The aims of this study were to evaluate the safety and the efficacy of the hydrochloric acid infusedradiofrequency ablation(HAl-RFA)using internally perfusion electrodes in an in vivo rabbit m
会议
OBJECTIVE: To evaluate the clinical efficacy and safety of transarterial chemoembolization(TACE)combined synchronous C-arm CT guided hydrochloric acid infused radiofrequency ablation(HRFA)and microwav
Purpose: To evaluate ablation duration that affects the size of ablation lesions and radiofrequency energy created from hydrochloric acid-in fused monopolar radiofrequency ablation.
会议
PURPOSE: Intensity-modulated radiation therapy(IMRT)is a new approach to the planning and delivery of radiation therapy(RT).
会议
Background: Laryngeal squamous cell carcinoma(LSCC)is the second most common upperaerodigestivemalignancy.
会议
Objective: To explore the difference of lesion sizes in ex vivo bovine liver created by Cool-tip? multi-electrode synchronous radiofrequency ablation via switching controller withconventional single e
Purpose:To explore the effects of changes in the gross tumor volume(GTV)on dose distribution in organs at risk(OARs)and healthy brain tissue in patients with gliomas.Methods:Eleven patients suffering
Purpose:To investigate the accuracy of brachytherapy treatment planning system(TPS)dose distribution calculations for brachytherapy employing a shielded vaginal cylindrical applicator that reduces the
Purpose:The increasingly attractive stereotactic body radiation therapy(SBRT) for stage I lung cancer is accompanied by a large amount of monitor units(MU),leading to excessive out-of-field dose and p
会议
Purpose:Development of MR/CT compatible and tissue-equivalent phantom was proposed for MRI-only based radiotherapy.Materials and Methods:The MR/CT compatible and a new tissue-equivalent phantom was de