Voxel-Based Morphometry with DARTEL Registration Improves Standard Registration

来源 :长江2011国际医学影像物理和工程应用大会暨第六届中国医学影像物理学术年会 | 被引量 : 0次 | 上传用户:objzobjz3
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background and objective Recent studies showed a controversy about whether DARTEL had significant improvement over standard registration in VBM analysis.In the current study,the primary objective was to evaluate the consistency of VBM analysis with DARTEL and standard registration.
其他文献
Purpose Malignant gliomas are almost uniformly fatal and display exquisite radiation resistance.Mutations in P53 tumor suppressor gene occur correlation with improved survival and enhanced respond to
会议
Objective: Establish a three-dimensional (3D) visualization system of medical images.Threedimensional visualization plays an essential and crucial role in disease diagnosis and treatment planning of p
To better explore the abundant information of brain regions involved in functional magnetic resonance imaging (fMRI) data during task status,especially the pattern of information transfer concerned in
Introduction Imaging is an essential tool to facilitate clinical diagnosis in ophthalmology.Currently most of the medical images are analyzed by human graders,which is very subjective.In this paper,co
会议
In this study,we developed a method of estimating the cerebral metabolic rate of glucose (CMRglc) using one sample of the input function in cerebral 18F-Fluoro-deoxigen-glucose (18F-FDG) positron emis
Focal spot size is an important factor that affects the spatial resolution and the projection image unsharpness.More seriously,the size and position of the focal spot may change as time goes or when t
目的 研究3D影像对观看者的影响,探讨脑电信号的功率谱特征与观看者不适感之间的联系,寻找用脑电信号的特征评价3D影像导致不适感的客观指标.方法 分别在3D和2D两种实验条件下,对实验前静息和实验过程中的脑电信号进行功率谱密度分析,采用统计分析方法进行假设检验并对照分析.
会议
[PURPOSE] To evaluate the accuracy (-)f the geometric calibration method for projection matrix computation and geometric parameter extraction,a cone-beam CT with a fiat-panel detector was simulated.MA
会议
Objective To present the methods of medical image quality assessment and optimization.Methods Based on human vision characteristics,the image vision quality parameters were analyzed in order to find t
呼吸运动引起较大幅度的胸腹部器官运动,造成传统CT图像上的运动伪影,影响放疗精确度及效率。四维CT(four-dimensional computed tomography,4DCT)技术能够提供反映内部器官运动的四维图像,有助于提高放疗精确度。传统4DCT技术在低剂量时将产生图像噪声及伪迹,且依赖于外部呼吸监测系统,无法在常规CT机上实现,使得设备昂贵。针对上述问题,本文提出基于图像最小边界不连