Effect of whole carbon fiber couch and virtual couch of VARIAN Linear Accelerator on radiotherapy do

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:ljnbba
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective:To study the effects of whole carbon fiber couch and virtual couch of VARIAN Linear Accelerator on radiotherapy dose of high energy X-ray.Methods:The solid water phantom was fixed at the center of treatment couch,to change the gantry angle,the different high-energy X-ray penetrated couch from different angle of gantry,and the penetration factor of X-ray was calculated by comparison and measurement.Radiotherapy plans with couch and non-couch were designed applying treatment planning system.Results:The penetration factor of each position,namely,thin,medium and thick,was at the lowest level,respectively,at gantry angle 110° for 6 MV and 15 MV X-ray following the change of incident gantry angle,the corresponding F was separately 0.9510,0.9496,0.9409 and 0.9668,0.9645,0.9600.The percentage difference between the measured value of these three positions of couch and the corresponding position of IGRT virtual couch reached the maximum level at gantry angle 160°,which were 2.79%,2.37%,1.81%and 1.15%,0.90%,0.53%,respectively.The variation trend of percentage difference between the measured value of these three positions of couch and the calculated value of non-virtual couch gradually decreased complying with the increase of couch thickness and X-ray energy.Also,value of PD reached the maximum level at about gantry angle 160° for 6 MV and 15 MV Xray,which were 2.06%,1.33%,0.50%and 0.50%,0.17%,-0.43%.Conclusion:Penetration factor decreases along with the couch thickness increase.The higher X-ray energy is,the bigger the penetration factor is.Under the condition of same X-ray energy,penetration factor gradually decreases with the couch thickness increase,meanwhile,penetration factor gradually increases along with the energy increase,that is to say,penetration factor for 15 MV X-ray is bigger than that for 6 MV X-ray,when penetrating the same medium.Under the condition of different X-ray energy,the variation trend of percentage difference between the measured value of three positions of treatment couch and the corresponding position of IGRT virtual couch is similar to penetration factor,namely,percentage difference gradually increases with the gantry angle increase.Under the condition of same X-ray energy,the percentage difference gradually decreases following the increase of couch thickness and X-ray energy.The variation trend of percentage difference between the measured value of three positions of couch and the calculated value of non-virtual couch gradually decreased complying with the increase of couch thickness and X-ray energy,however,the overall difference is lower than the calculation value of virtual couch.After designing radiation treatment planning with virtual couch using TPS,the measured dose is more close to the calculated dose.Therefore,it is necessary to use virtual couch when designing radiotherapy treatment plan in the clinical.
其他文献
Objective:To study acute radiation-induced small bowel damage in patients with abdominal-and-pelvic tumor radiation therapy,in order to explore the clinical and dosimetric factors associated with grad
Objective The paper is to perfect complete the QA process by developing of the method used to fast verify the center position of body patient which are treated with Cynthia Gamma Knife.method The rese
Purpose:Radiation therapy oncology group(RTOG) 0631 suggest different planning method in spine stereotactic body radiation therapy(SBRT) according to location of cancer owing to its distinct shape.The
会议
Purpose The difference between three-dimensional(3D)and four-dimensional(4D)dose is effected by factors such as tumor size and motion amplitude.To propose quantitative results about the effect by thes
Purpose:Radiotherapy has been increasingly adopted in clinical practice for tumor treatment.FDS Team has been focused on the key physical and technical issues of accurate radiotherapy for many years.A
Purpose:To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy(VMAT),high-dose-rate(HDR)brachytherapy,and low-dose-rate(LDR)permanent seeds implant for lo
Purpose:To improve the set up accuracy of patient alignment,we developed a new real time patient alignment monitoring system based on laser sensing technology and evaluated its feasibility.Methods:The
会议
Introduction:Radiotherapy is a standard treatment of breast cancer after complete surgery.The curved surface of the breast and the geometry that is laid near the critical organs,treatment techniques f
Objective:To select reasonable treatment methods for liver tumor,the dose distribution by three-dimensional treatment planning system(TPS)for target area and normal liver around liver tumor in four in
Purpose:To compare dosimetry difference in the whole central nervous system(CNS)radiotherapy in both intensity-modulated radiation therapy(IMRT)and three dimensional conformal radiation therapy(3D-CRT