EFFECT OF SMALL PRIME VOLUME ON INCIDENCE OF BLOODLESS PAEDIATRIC CARDIAC SURGERY

来源 :第七届亚洲体外循环学术会议暨第三届全国体外循环学术会议 | 被引量 : 0次 | 上传用户:odeartiger
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Small prime volume is a major factor in decreasing homologous blood transfusion.From January 2006 to June 2007,367 patients weighing less than 15Kg underwent surgery:Group 1,214 neonates and infants (rang 2.1 ~ 1 l kg,mean 4.5 ± 1.5kg) with prime (125ml) composed of blood (fresh frozen plasma [FFP] and packed red blood cells [PRBC]); Group 2,153 infants and children (rang 5.7 ~ 15kg,mean 9.7 ± 2.7kg)with prime (155ml) composed of blood or of lactated Ringer solution (50%) and hydroxyethyl Starch (50%).We do not use hemofiltration or cell salvage intraoperatively.
其他文献
Objective:To summarize the way and management of cardiopulmonary bypass (CPB) with totally robotically assisted cardiac surgery.Methods:Total 23 patients underwent cardiac surgery with da Vinci S robo
Objective:Cardiopulmonary bypass (CPB) is known to cause part of the systemic inflammatory reaction after cardiac surgery that can be responsible for organ failure.A novel technique based on a minimal
会议
Objective:One of the complications of CPB is the systemic inflammatory response syndrome (SIRS).Recent developments tend to minimize the biological impact of CPB in using miniaturized closed circuit w
会议
Objective:The aim was to compare influence of standard extracorporeal circuit (SECC) and mini-extracorporeal circuit (MECC) on parameters of the acid-base balance,gas and electrolytes of blood,lipid p
会议
The use of hyperthermia as an adjunct to chemotherapy in the treatment of peritoneal carcinomatosis is a technique for patients who otherwise have a poor prognosis for survival.Abdominal or pelvic can
会议
Objective:The early thrombosis of venous grafts after coronary arteries bypass grafting (CABG) is one of the reasons of relapse of an angina pectoris or development of a myocardial infarction.Intraope
会议
Introduction:The CDI-500 (Terumo Corporation,Japan) in-line blood gas monitoring device has been in clinical practice for over a decade.Few randomized studies have evaluated the value of this device w
会议
Objective:One of the most frequent complications after operations with cardiopulmonary bypass (CPB) is renal dysfunction which arises at 29% of patients.Aprotinin traditionally used at cardiac surgery
会议
Port access surgery as it is performed today,is by far,not an easy task.Its become very clear that with proper understanding and education of these techniques and procedures the likelihood of success
会议
Results of retrospective research of influence of 2 million KIE of aprotinin (group 1) and aminocapronic acid (group 2) on size postoperative blood loss at patients after cardiopulmonary bypass (CPB)