PET/CT Image Registration to Reduce Respiratory Mismatch

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:heeroyuyo
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose: PET/CT images fusion accuracy may suffer from respiratory motion of body.To get better clinical images,it is necessary to correct PET data for motion artifacts.Methods: A novel high performance 3D combined registration method is applied to two delayed CT images to obtain the transformation field between two images.The transformation field can be used to correct the deformation between two PET/CT images.The combined registration method contains four main steps: pre-location of organ(liver),pre-rigid registration of whole image,accurate rigid registration of organ(liver)and accurate non-rigid registration of whole image.All registration algorithms are based on mutual information.Results: The chess board interval fusion results between two delayed CT images show smooth boundary of liver,lung,kidney,spleen and even small vessel.The combined registration method could correct the respiratory motion artifacts of body in a details level.Conclusions: The proposed methods reduce mismatch between two sets of PET/CT fusion images due to respiratory motion.The method could be used to register PET and CT images and to reduce the respiratory artifact in one PET/CT scan.
其他文献
目的:本研究拟通过对大凉山西昌地区彝汉混居区艾滋病病毒感染者/病人进行中医体质辨识、分类,为此类地区艾滋病中医药临床救治提供相应的研究依据。方法:采用现状调查的方法,根据患者回答情况,如实填写《中医体质辨识量表》,并将所填内容输入计算机“中医体质辨识软件”上海国臣软件公司提供判定体质类型。
目的 观察断经缩瘤汤治疗围绝经期子宫肌瘤肾阴虚血瘀证的临床疗效.方法 将确诊为围绝经期子宫肌瘤患者60 例按随机、阳性药物对照原则分为治疗组和对照组,治疗组服用断经缩瘤汤,1 日1 剂,1 日3 次,对照组服用米非司酮,每日1 次,每次12.5mg,睡前服.12 周1 疗程.
目的:探讨针刺百会穴对AD 模型鼠大脑皮质组织小胶质细胞分泌前炎症介质TNFα的影响。方法:Aβ1-42 侧脑室注射造AD 模型大鼠,针刺百会穴治疗21 天,免疫荧光观察大鼠大脑皮质小胶质细胞分泌TNFα 的情况。
目的:肩部巨大韧带样纤维瘤手术切除难度巨大,本研究讨论其手术入路选择及评估外科疗效.方法:2003年6月~2012年6月21例肩部巨大韧带样型纤维瘤病患者,11例初诊,10例具有外院手术史.肿瘤大小7.0cm~19.0cm,平均10.5cm.在已有肩部分区基础上将肩部分为四区,Ⅰ区为肩胛下肌以前,包含胸大、小肌,Ⅱ区为腋后壁肌区,Ⅲ区为肩胛区,Ⅳ区为三角肌区.
Introduction:Polymer gels are 3-dimensional(3D) dosimetric tools used to evaluate radiation dose-relatedradiation-induced polymerization.When using a polymer gel as a phantom,it is possible to measure
会议
Purpose: Segmental scanning protocol of Multi-energy computed tomography(MECT)is an easy-to-implement and no-extra dose induced way realized in conventiaonal CT,but the reconstruced image was degraded
INTRODUCTION The artifacts due to physiologic motion when using the Cartesian strategy of magnetic resonance imaging are well known [1] and many techniques of reducing the motion artifacts were presen
Purpose:Head motion in PET/CT leads to artifacts due to the mismatch of PET and CT images.This work aims at reducing motion artifacts in PET image reconstruction.Methods:The correction method for head
Purpose:It has been known that images reconstructed with filtered back projection(FBP) techniques areoften inadequate in CT.Iterative reconstruction(IR) has the potential to allow reducing dose whilem
会议
Purpose:Digital breast tomosynthesis(DBT) has been considered as an innovative imaging modalitybecause it can solve the problem of poor depth resolution in conventional digital mammography by utilizin
会议