Consequences of energy renovation on indoor air quality in kindergartens

来源 :建筑模拟(英文版) | 被引量 : 0次 | 上传用户:hurusato09
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Educational facilities present the largest share of the oldest buildings in Europe and contribute greatly to high energy use. In order to stimulate building energy efficiency, the present day extensive renovations are going towards narrow-minded measures with minimisation of ventilation losses by minimal permissible design ventilation rates. In Slovenia, such an approach is supported by national legislation and results in uncomfortable and unhealthy conditions as well as other negative health-related outcomes. The main purpose of this study was to critically assess the relevant problems related to the deteriorated indoor air quality (IAQ) in a renovated kindergarten. First, a systematic literature review on health outcomes related to inadequate ventilation in kindergartens is presented. Second, in a case study on a renovated kindergarten in Slovenia, IAQ and energy use are critically assessed for 13 sets of scenarios, where design ventilation rates variated according to legal requirements and recommendations. CO2 concentrations were simulated in two model playrooms with CONTAM 3.2. Indicators of energy use were simulated with EnergyPlus 8.8.0, with and without recuperation. The results of literature review revealed that insufficient ventilation was positively associated with higher prevalence of negative health outcomes. Simulations of CO2 in two playrooms showed that the highest CO2 concentrations resulted in scenario 1 with 0.5 ACH and scenario 4 with 1.5 m3/(h·m2), both defined by national rules. The calculated values in both scenarios exceeded the national required value for CO2 (1667 ppm) by 2.5 times and 3 times, and the recommended value for Category I of indoor environmental quality defined by EN 15251: 2007 (750 ppm) by 5.6 times and 6.6 times. Scenario 9_Cat I with 14 L/(s·m2) defined by EN 15251: 2007 resulted in minimal CO2 (playroom 1: 512 ppm, playroom 2: 536 ppm) and corresponded to the recommended values defined by studies, where no health effects were observed. Energy simulations showed that the application of recuperation in scenario 9_Cat I, minimised heat losses by ventilation by factor 3.6 in playroom 1 and 3.5 in playroom 2 compared to losses without recuperation. Design ventilation rates defined by the design approach of minimal permissible value resulted in conditions relevant for Category IV of indoor environmental quality and have to be prevented. Recommendations in national policies and environmental health strategies can be used in all stages of healthy and energy efficient design of buildings.
其他文献
伴随着资本流动的加剧及企业之间竞争的激烈,并购因为其独特的优势,逐渐成为企业提高自身市场竞争力的重要方式。但是在实务中,大多数企业面临的不是并购成功所带来的收益,而是并购失败之后的财务负担。分析并购失败的原因,并购成本居高不下是一个重要方面,而这其中不乏人为因素的作用。对于企业来说,高管团队是企业进行战略决策的成员,而CFO作为其中的一员,必然会参与企业重要的战略决策,其专业胜任能力的高低必然会对
The forced convection (air supply jet) and the natural convection (thermal plume of passenger) co-exist in an aircraft cabin simultaneously. Due to the notable
Improving the wellbeing of the occupants is the main challenge in the building design field. This work aims optimizing the design of a free-running residential
科技进步对国家经济增长起重要作用。科研单位作为一种以从事研究开发为主要业务的机构,广泛的存在于各地市、各行业、各领域,是承担国家科技进步创新的重要组织之一,其中公益类科研单位主要依托财政科技计划(专项、基金等)作为科研经费的主要构成。近年来,国家不断加快科技计划改革的步伐,同时加大力度整合对原有科技计划,相关科技计划有所减少,导致公益类科研单位争取科技计划的难度不断增加,不断出台的各项新的经费管理
Industrial ventilation and heat dissipation time are important factors due to high temperature and emissivity coefficients of heat source conducive to radiation