设已知: 1.水工建筑物正常拦蓄水位(НПГ)。 2.考虑水库淹没条件,给定最高洪水位(ГРП)高于正常拦蓄水位的最大许可数值:Δh。此外已给:泄水结构溢流堰顶的高程;库水位与库容积关系曲线:W=f(h);和设计洪水流量过程线:Q=F(T)。要求推算出:通过溢流堰的最大泄出流量,从而拟定其必需之尺寸。问题的复杂性在于不可能直接寻得解答。一般有关书籍在已定的泄水结构物尺寸的情况下,对于最大泄出流量推算问题已有了较详尽的论述,但作者们涉及本文所述者不多。
Set known: 1. Hydraulic structures normal water level (НПГ). 2. Considering the condition of reservoir submergence, the maximum allowable value for the given maximum flood water level (ГРП) above the normal water cut level: Δh. Also given is the elevation of the overflow weir crest; the relationship between the reservoir water level and the volume of the reservoir: W = f (h); and the design flood discharge process line: Q = F (T). It is required to calculate: the maximum discharge flow through the weir to develop its required size. The complexity of the problem is that it is impossible to find the solution directly. In the case of a book about the size of a discharge structure, the book on general discharge has been discussed in detail for the calculation of the maximum discharge flow rate, but the authors are not involved in this article.