Screening for amblyopia among grade-1 students in primary school with uncorrected vision and stereop

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:accpaccp1234
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Screening for amblyopia at earliest is important for early treatment and better prognosis.This study aimed to evaluate the validity of uncorrected distant and near visual acuity (VA) and stereoacuity for screening amblyopia in grade-1 students in primary school in central China.Methods By stratified cluster sampling,3112 grade-1 students from 11 Anyang primary schools were selected for the study.All the participants underwent uncorrected distant and near VA,stereopsis test,cycloplegic refraction,best corrected VA (BCVA),cover test,and ocular movement examination.VA was measured with a logarithm of the minimum angle of resolution (IogMAR) chart.Stereoacuity was measured with the Lang Ⅱ stereo card and TNO test.Amblyopia was defined as the BCVA less than or equal to 0.1 IogMAR units of any eye in the absence of significant pathological abnormalities.The sensitivity,specificity,and positive and negative predictive value of uncorrected VA and stereoacuity for amblyopia were analyzed.Results Out of the 3112 eligible students,2893 (92.96%) completed the examinations.The average age of the students was (7.10±0.41) years.Screened by distant VA with low cutoff (IogMAR 0.1),high cutoff (IogMAR 0.0),and near VA (IogMAR 0.0),31.64%,73.18%,and 50.23% students were abnormal,respectively.Screened by stereopsis test,only 4.69% students were abnormal.Diagnosed by a senior pediatric ophthalmologist,61 students had amblyopia.The sensitivities of distant VA with low/high cutoff and near VA were 92.31%,100%,and 80.77%,respectively,whereas that of stereoacuity by TNO test was 15.38%.Simultaneous testing of either two of the three tests improved the sensitivity.Conclusions Distant VA test of high cutoff alone displays a high sensitivity but a low specificity.Simultaneous testing of distant VA of low cutoff and stereoacuity is a better choice to balance between sensitivity and specificity.
其他文献
由于倒角在构造机械零件中用得非常普遍,因而在特征识别中,研究针对倒角特征的识别方法具有一定的实际意义。本文基于条件匹配的原则,提出一种识别倒角特征的新方法,此方法可以自动识别出一般零件的倒数,具有较强的通用性。
以通河站实测水文资料为依据 ,分析了影响“5 7 9”和“91 8”洪峰水位 (流量 )诸因素 ,得出了通河站这两年洪峰水位差异原因。 Based on the measured hydrological data o
振动沉管灌注桩具有现场就地成桩 ,施工简便 ,速度快 ,工期短 ;对地层穿透力较强 ,成桩质量容易保证 ;单桩承载力相对其他桩型高 ;施工环境好 ,噪音较低 ,作业场地小 ;经济效
To the editor:Pregnancy complicated by non-Hodgkns lymphoma (NHL) has rarely been reported.It has been estimated that about 0.76% (0-1.8%) of NHL cases are accomp
期刊