电力系统运行的经济性与电能质量、无功功率有重大的关系。若对无功补偿装置维护管理不到位,将造成无功补偿投入不足,影响电能质量及加大电能损耗。文章针对无功补偿装置运行管理过程中存在的问题,从接线线径选择、装置接线要求、安装规范、维修要求、电容容量选择等各方面提出了具体措施,以确保无功补偿功率因数满足要求,达到降低电量损耗,保证电能质量的目标。
The economy of power system operation has a significant relationship with power quality and reactive power. If the maintenance of reactive power compensation device is not in place, will result in insufficient reactive power compensation, affecting power quality and increase power loss. In this paper, according to the problems existing in the operation and management of reactive power compensation devices, specific measures are proposed in terms of wiring diameter selection, device wiring requirements, installation specifications, maintenance requirements and capacitance capacity selection to ensure that the reactive power compensation power factor meets the requirements , To achieve the goal of reducing power consumption and ensuring power quality.