本文通过考察各因素对样品消解效果的影响及对石墨炉原子吸收各条件进行优化 ,建立一种快速、有效的中药中镉含量的检测方法 ,方法检出限为 0 0 1 1 9ng·mL- 1,线性范围 0 0 0 6~ 2ng·mL- 1,样品测定回收率 91 7%~ 1 0 4 3% ,结果满意
In this paper, by examining the impact of various factors on the digestion effect of the sample and optimizing the conditions of graphite furnace atomic absorption, a rapid and effective method for the determination of cadmium in traditional Chinese medicine was established. The detection limits were 0 0 1 1 9 ng · mL- 1, the linear range is 0 0 6 ~ 2 ng · mL -1, the recovery of the sample is 91 7% ~ 1 0 4 3%, the result is satisfactory