论文部分内容阅读
建立了离子对高效液相色谱法分离与测定复方制剂(新灭菌)中的羟氨苄青霉素及氟氯青霉素含量法。采用C8.10μm,4.6×200mm柱(大连化物所Spherisorb),以含1.4%十六烷基三甲基溴化铵的pH6.5磷酸盐缓冲液-乙腈(68+32)为流动相,在紫外检测器254nm波长处检测,线性范围为0.25~2mg/mL,r=0.9999(n=5),羟氨苄青霉素及氟氯青霉素平均回收率分别为99.5%及100.7%(n=5)。精密度:羟氨苄青霉素及氟氯青霉素日内(4h)平均RSD(相对标准偏差)均为0.8%(n=15),日间(2h)平均RSD分别为0.6%和0.7%(n=3)。
A method for the separation and determination of amoxicillin and chlorfluralin in compound preparations (neo-sterilization) was established by ion-pair high performance liquid chromatography. Using a C8.10 μm, 4.6 × 200 mm column (Spherisorb, Dalian Institute of Chemical Industry) and a mobile phase of 1.4% hexadecyltrimethylammonium bromide in pH 6.5 phosphate buffer-acetonitrile (68 + 32) , With a linear range of 0.25-2 mg / mL at a wavelength of 254 nm at UV detector (r = 0.9999, n = 5). The mean recoveries of amoxicillin and chlorfluracycline were 99.5% and 100%, respectively .7% (n = 5). Precision: The mean RSD (n = 15) for both amoxicillin and flucillin during the day (4h) were 0.8% (n = 15), and the average RSD was 0.6% and 0.7 % (N = 3).