【摘 要】
:
The limitation of paraxial condition of paraboloid refracting system in performing fractional Fourier transform acts like an aperture, which makes the system different from ideal systems. With aperture expanded as the sum of finite complex Gaussian terms,
【机 构】
:
DepartmentofPhysics,LudongUniversity,Yantai264025
【出 处】
:
ChineseOpticsLetters
论文部分内容阅读
The limitation of paraxial condition of paraboloid refracting system in performing fractional Fourier transform acts like an aperture, which makes the system different from ideal systems. With aperture expanded as the sum of finite complex Gaussian terms, a more practical approximate analytical solution of fractional Fourier transform of Gaussian beam in an apertured paraboloid refracting system is obtained and also numerical investigation is presented. Complicated and practical fractional Fourier transform systems can be constructed by cascading several apertured paraboloid refracting systems which are the simplest and the most basic units for performing more precise transform.
其他文献
在制备石墨烯/聚乳酸(PLA)复合材料的基础上,利用熔融沉积成型技术快速制备了单层均质样件,研究了石墨烯含量对其电磁参数的影响规律,并基于传输线理论计算分析了其吸波效果;选择石墨烯含量较低的复合材料作为透波层的打印材料,石墨烯含量较高的复合线材作为吸收层和再次吸收层的打印材料,并基于四分之一波长匹配理论确定了吸收层、再次吸收层的匹配厚度范围。设计制造了由不同石墨烯/PLA复合材料组合而成的三层吸波体,测试结果表明:三层吸波体的吸波效果远优于单层均质吸波体,且当选取石墨烯质量分数分别为5%、7%、8%的复合
提出一种基于单柱透镜旋转调制的光学扫描成像系统,样品的完整波前信息可以通过柱透镜旋转调制的多幅强度图样迭代重建。此外,柱透镜的旋转角度作为该系统的一个关键参数,其值通过基于Radon变换的数值计算方法得到,摆脱了对高精度旋转设备的要求。该成像系统的可行性在仿真和实验结果中均得以验证。与轴向多距离扫描成像系统相比,该成像系统中各光学元件在轴向位置保持固定,数据获取速度得以加快且轴向采样率保持固定,不
基于不同位置的动态光路延迟装置和位于罗兰C主台的纠缠源信号,通过主台非平衡M-Z(马赫-曾德尔)干涉仪检测不同路径纠缠光场的相位差信息,得到罗兰C主、副台的同步时差信息。理论和仿真分析结果表明,在相位差为0.5π时,能得到最佳时差信息,精度能达到数十皮秒级别。相较于原有的主从同步或自由同步等方式,此方案不需要测量脉冲到达时间,而且能够突破量子噪声极限,有效提高了测时精度。
The broad luminescence spectrum of a thermally activated delayed fluorescence (TADF) organic light-emitting diode (OLED) is a critical issue to overcome for its application in high-color-purity displays. Herein, a novel device structure that utilizes the
利用合肥郊区夏季三维超声风速计测量的虚温、风速和Li7500二氧化碳和水汽分析仪获得的水汽浓度资料,从两个方面研究湿度起伏对三维超声风速计测量可见光折射率结构常数C2n的影响。对超声虚温进行湿度修正后,得到真实温度,比较了由超声虚温和真实温度分别计算得到的温度结构常数C2T。另一方面,计算出温湿度相关项CTq和湿度结构常数C2q各自对C2n的贡献。结果显示真实温度计算得到的C2T与超声虚温计算得到的C2Ts有显著差别,很多时候两者的差异超过10%。CTq对C2n的贡献较大,可超过10%,不可忽略;而C2q
利用Z扫描系统研究了多层石墨烯非线性光学吸收特性。结果表明多层石墨烯在激光作用下具有反饱和吸收特性, 且非线性折射系数为正。随着层数增大, 非线性光学吸收系数减少得慢一些。基于微观尺寸效应, 2~5层石墨烯的叠层方式也会影响到非线性吸收系数的值。另外, 激光的强度、中心波长和脉宽等因素都会影响样品非线性光学吸收系数的结果。石墨烯具有非常优良的非线性光学特性, 为其制成非线性光学器件提供了有效的实验依据。
An enhancement method of rapid lifetime determination is proposed for time-resolved fluorescence imaging to discriminate substances with approximate fluorescence lifetime in forensic examination. In t
波导型可调控检偏器是集成光子系统中的核心元器件之一,其输出偏振态具有动态调控特性,在集成光子系统中具有重要的应用价值。提出了一种新型波导型可调控检偏器,该器件采用偏折倒脊型波导结构,利用液晶材料的各向异性和大双折射特性并基于电光效应实现对光束偏振态的调控,完成横电波和横磁波的可调控输出。采用光束传播法对所提器件的光学特性进行了模拟分析,模拟结果表明,该新型波导型可调控检偏器的消光比高达29.8 dB,光损耗仅为0.002 dB,且该器件对波长和制作工艺误差不敏感。所提器件具有动态调控简便、易于设计和制作、