多原因造成印度大停电2012年7月30、31日,印度连续发生两次大停电事故。其直接原因是重载情况下单一元件距离Ⅲ段保护误动引发连锁反应,最终导致系统崩溃,而深层次的原因则与技术、管理和体制均有关系,是各方面因素共同作用的结果。事故前印度电网大量输电线路停运使得网架结构被大幅削弱,电网抵御事故的能力大大降低。两次事故发生前,电网中均有大量线路停运。根据印度官方事
Many Causes a Major Blackout in India July 30-31, 2012 Two major blackouts occurred in India. The direct reason is that under the condition of heavy load, the protection of a single element from section Ⅲ is triggered by a chain reaction which eventually leads to system collapse. The underlying causes are related to technology, management and system, and are the result of the interaction of various factors. Before the accident, a large number of transmission lines in India’s power grid were out of operation, which resulted in the grid structure being significantly weakened and the power grid’s capacity to withstand accidents greatly reduced. Before the two accidents, a large number of lines were out of service in the power grid. According to Indian official matter