论文部分内容阅读
Mechnism of treatment and remediation of synthetic Cu2+ polluted water body by membrane and electro-winning combination process was investigated.The influnce of electrolysis voltage,pH,and electrolysis time on the metal recovery efficiencies were studied.Relationship between trans-membrane pressure drop (ΔP),additions ratio,initial Cu2+ concentration on operating efficency,stability of membrane and the possibility of water reuse were also investigated.The morphology of membrane and electrodes were observed using scanning electron microscopy (SEM),the composition of suface deposits was ascertained using combined energy dispersive X-ray spectroscopy (EDX) and atomic absorption spectrophotometer.The results showed that using low presure reverse osmosis (LPRO),the Cu2+ concentration could increase from 20 mg/L to 100 mg/L or even higher in the concentrate solutions and permeate water conductivity could be less than 20 μS/cm.The addition of SDS can improve the Cu2+ removal efficiency,while EDTA had little side influence.In electro-reduction process,using plante electrode cell,Cu2+ concentration can be further reduced to 5 mg/L,and the average current efficiency ranged from 9% to 40%.Using 3D electrolysis treatment,Cu2+ concentration could be reduced to 0.5 mg/L with a current efficiency range 60%-70%.