Correlation of eosinophil counts in induced sputum and fractional concentration of exhaled nitric ox

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:zel1988
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background The airway inflammation could be assessed by some noninvasive approaches.To investigate the value of eosinophil counts in induced sputum and fractional concentration of exhaled nitric oxide (FENO) for the regimen adjustment in patients with asthma,the correlation was analyzed between the two parameters and lung function parameter (forced expiratory volume in one second (FEV1)).Methods Sixty-five outpatients with mild to moderate non-exacerbation asthma from Beijing Chao-Yang Hospital were enrolled as treatment group.Combined medications of inhaled corticosteroids plus long-acting beta-2 agonist were administered for one year.Lung function parameters,eosinophil counts in induced sputum,concentration of exhaled nitric oxide and the Asthma Control Test scores were recorded,at regular intervals in the follow-up period.Twenty-one healthy volunteers were enrolled as control group and underwent examination of eosinophil counts in induced sputum,lung function and concentration of exhaled nitric oxide.Results Sixty-three subjects from treatment group completed follow-up period for one year or longer.Mean FEV1 value of the 63 subjects was (2.75±0.54) L at baseline,(2.97±0.56) L and (3.07±0.52) L at month 3 and month 6,respectively,and maintained as (3.14±0.51) L in the following six months.Mean FENO decreased from (61±25) parts per billion (ppb) at baseline to (32±19) ppb at month 3 (P <0.05),and continued to decrease to (22±12) ppb at month 6,the difference being significant when compared to both baseline and control group ((13±8) ppb).Mean eosinophil counts decreased to (0.032±0.011) ×106/ml at month 3,which was significantly different from baseline ((0.093±0.023)×106/ml) and the control group ((0.005±0.003) ×106/ml (both P <0.05).The eosinophil counts in induced sputum correlated positively with concentration of FENO in the first six months (all P <0.05).The concentration of FENO had a significant negative correlation with FEV1 value (all P <0.05) in any time point in the follow-up period.The Asthma Control Test scores were 18±5,19±7,23±2,24±1 and 24±1 at months 1,3,6,9 and 12,respectively,which were significantly different from the score at baseline (14±3) (P <0.05 ).The most rapid clinical effect was observed at the second month after treatment.Conclusion Eosinophil counts in induced sputum and FENO are sensitive parameters to detect airway inflammation and may be useful in evaluating the efficacy of treatment and adjusting medication regimens.
其他文献
Background The non-hemodynamic effects of angiotensin receptor blocker (ARB) in the delay of progression of chronic kidney disease (CKD) remain unclear.In this
Background Molecular testing is more precise compared to serology and has been widely used in genotyping blood group antigens.Single nucleotide polymorphisms (S
Background Severe bilateral carotid stenosis caused by atherosclerosis has not been unusual in the elderly.Such patients have high stroke risk.Many studies show
Background The rapidly activating delayed rectifier potassium current (/Kr),whose pore-forming alpha subunit is encoded by the human ether-a-go-go-related gene
Background Durable polymers used for first-generation drug-eluting stents (DES) potentially contribute to persistent inflammation and late DES thrombosis.We re
本文针对人影作业中使用的37mm高炮,给出了37mm高炮同步装置构造,同步装置的作用和原理。分析讨论了在射击中出现不同步发射的故障和原因,捐出了解决射击时双管不同步发射故
针对电路板雕刻机存在的没有距离显示和超限保护的具体情况,讨论了利用嵌入式工控模块所实现的系统硬件和软件设计。给出了超声测距的原理分析,采用超声波物位变送器实现高精
Background Previous studies have proved the renal protective effects of anisodamine in patients with septic shock.The aim of this study was to investigate aniso
Background Induction therapy are utilized to achieve an adequate immunosuppression at the time of transplantation.The use of basiliximab or anti-thymocyte globu