我科自1986年9月起半年多来应用“北京儿研所”与“北京市锋利刀子厂”,合作研制的QSW-1型多用给氧湿化器,用其经鼻塞呼吸道持续正压(CPAP)给氧,在血气监测下,治疗了新生儿呼吸衰竭24例,除2例自动出院外,均全部成活: 临床资料一、一般资料本文24例,重症肺炎9例,胎粪吸入综合征4例,早产儿反复呼吸暂停4例,缺氧缺血性脑病4例,RDS1例,羊水吸入综合征2例。按血气分型:Ⅱ型呼吸衰竭轻症23例、重症1例。男婴10例,女婴14例,发病
Since September 1986, our department has applied the “Beijing Institute Research Institute” and “Beijing Sharp Knife Factory” for more than six months. The QSW-1 multi-purpose oxygen humidifier has been developed in cooperation with the company. CPAP) to oxygen, in the blood gas monitoring, treatment of 24 cases of neonatal respiratory failure, in addition to two cases of spontaneous discharge, all survived: Clinical data First, the general information in this article 24 cases, 9 cases of severe pneumonia, meconium aspiration syndrome 4 cases, 4 cases of repeated apnea in preterm infants, 4 cases of hypoxic-ischemic encephalopathy, RDS in 1 case and amniotic fluid aspiration syndrome in 2 cases. According to the type of blood gas: type Ⅱ respiratory failure mild in 23 cases, severe cases in 1 case. 10 cases of baby boy, 14 cases of baby girl, the incidence