介绍了海尔绿城·奥体酒店空调冷热源、风系统、水系统的设计。根据使用功能的不同采取不同的风系统组合形式,酒店大堂及共享大厅采用一次回风的全空气系统,侧送及喷口送风,集中回风。冬季结合低温热水地板采暖系统,保证该区域的温度场均匀,酒店客房等小房间采用风机盘管加新风系统,新风处理到室内焓值;空调水系统采用一次泵变流量,变频调节四管制系统;制冷主机、水泵、新风机组、空调机组、风机盘管等根据其特点采取不同的控制策略。
Introduced Haier Greentown · Olympic Hotel air conditioning hot and cold air source, wind system, water system design. Different wind system combinations are adopted depending on the functions to be used. A full air system of the return air is used in the lobby and the shared hall, and air is sent to the side and the air outlet to concentrate the return air. Winter combined with low temperature hot water floor heating system, to ensure uniform temperature in the region, the hotel rooms and other small rooms with fan coil plus fresh air system, fresh air to indoor enthalpy; air conditioning water system uses a pump variable flow, frequency control four System; cooling host, water pump, fresh air unit, air conditioning unit, fan coil and so on according to its characteristics take different control strategy.