Objective To determine whether the level of serum cardiac troponin T (cTnT) was increased in patients with congestive heart failure (CHF). Methods This study consisted of 265 patients with CHF and 75 healthy people. Serum cTnT was measured by electrochemiluminescence immunoassay using an Elecsys 1010 automatic analyzer. Results cTnT concentration was 0.181±0.536 ng/mL in CHF patients and 0.003±0.001 ng/mL in controls (P35%, cTnT was 0.07±0.0 5ng/mL (P0.05, class Ⅱ vs class Ⅲ P