【摘 要】
:
Previous results show that the floating reference theory (FRT) is an effective tool to reduce the influence of interference factors on noninvasive blood glucose sensing by near-infrared spectros-copy (NIRS). It is the key to measure the floating reference
【机 构】
:
TianjinKeyLaboratoryofBiomedical,DetectingTechniquesandInstruments,CollegeofPrecisionInstruments
【出 处】
:
JournalofInnovativeOpticalHealthSciences
论文部分内容阅读
Previous results show that the floating reference theory (FRT) is an effective tool to reduce the influence of interference factors on noninvasive blood glucose sensing by near-infrared spectros-copy (NIRS). It is the key to measure the floating reference point (FRP) precisely for the application of FRT. Monte Carlo (MC) simulation has been introduced to quantitatively in-vestigate the effects of positioning errors and light source drifts on measuring FRP. In this article, thinning and calculating method (TCM) is proposed to quantify the positioning error. Mean-while, the normalization process (NP) is developed to significantly reduce the error induced by light source drift. The results according to TCM show that 7 m deviations in positioning can generate about 10.63% relative error in FRP. It is more noticeable that 1% fluctuation in light source intensity may lead to 12.21% relative errors. Gratifyingly, the proposed NP model can effectively reduce the error caused by light source drift. Therefore, the measurement system for FRPs must meet that the positioning error is less than 7 m, and the light source drift is kept within 1%. Furthermore, an improvement for measurement system is proposed in order to take advantage of the NP model.
其他文献
为了减小四频激光陀螺零漂的温度敏感性,对数学补偿模型和安装结构热设计进行了研究。通过高低温实验研究了四频激光陀螺零漂与温度的关系。第一次采用普通铜支架将四频激光陀螺固定在屏蔽盒内,由于两放电支路的温度变化不对称,温度变化率是数学补偿模型的显著项。第二次设计了专用铜支架,使两放电支路的温度对称地变化,因而温度变化率在数学补偿模型中的重要性大大降低。改进支架之后,补偿后的零漂残差从0.018 Hz降低到0.01 Hz,即便采用温度多项式补偿模型也能达到0.012 Hz。这些结果表明:在设计四频激光陀螺系统时,
We report a hybrid femtosecond laser system based on a femtosecond Yb-doped fiber laser and a Yb-doped potassium gadolinium tungstate (Yb:KGW) regenerative amplifier. To match the central wavelength of the seed source, a Yb:KGW crystal is used in the rege
锥形半导体激光器具有能够同时获得高输出功率和高光束质量的优良特点。介绍了分离电极锥形器件的锥角选择、制作工艺、光电特性等;分析了脊形区电流和锥形区电流对器件光束质量和近场特性的影响。制作的器件总腔长为5.5 mm(脊形区长度为1.5 mm,锥形区长度为4 mm),锥角为5°,器件输出功率为7 W。在脊形区电流为400 mA、锥形区电流为7 A时,器件的输出功率为6.4 W,光束质量因子M2为1.66(1/e2),亮度达到369 MW·
Shiva激光器系列中使用了三种尺寸的片状放大器——β、γ和δ。三种放大器有同样的结构,同样的外形、长度和同样的安装支架与Shiva空间行架相配。图1(见封三)所示为Shiva片状放大器的装配工序图列。放大器的装校装置设计成易于互换的金属板件,和V型架以致所有大小的片状放大器都可以安装。
The evolutions of polarization and orbital angular momentum (OAM) states of light in helically twisted birefringent photonic crystal fibers (TB-PCFs) are analyzed. It is shown that a circular polarization (CP) component (
在探索空间分束法消除椭偏测试中背反杂光干扰的过程中,发现该方案能够使光束在待测样品前表面聚焦,后表面发散,发散的背反光将无法进入到探测器中,从而消除背反光的影响。选用石英玻璃和氧化铌单层膜为实验样品,分为3组,分别采用直接测量、背部打磨和空间分束三种测量模式。实验结果表明,样品未经处理情况下,不同角度直接测量得到石英玻璃折射率值差别较大,经过背部打磨后不同角度下得到石英玻璃折射率趋向一致,而采用空间光学分束处理后,石英玻璃折射率在不同角度下测试获得相同的数据。最后采用空间分束法对氧化铌单层膜进行椭偏测量,
本文提出一种实时测量表面粗糙度的结构简单、光路调节方便的实验系统。用双棱镜产生的两束不同方向的平面波同时照射粗糙表面,从散射光场的相关度得到表面粗糙度。结果表明,选择较小的棱镜角和入射角,可使粗糙度的测量范围达1μm~40μm;实验结果与泰勒雪夫-5型粗糙度检查仪的测试值符合得较好。
根据波导激光器理论分析了φ=3~6 mm、N~1的一类内脏式CO2激光器输出支线的各种特点以及支线跳变现象.结果表明这是波导模的传输损耗d11参予支线竞争的结果.
In this letter, we propose a voltage-controlled optical filter based on electrowetting. The device is made of a transparent cubic cell filled with two immiscible liquids having three indium tin oxide electrodes fabricated on the bottom substrate of the ce