基于故障树分析的方法,结合大量国内外曾发生的事故,以空分主冷凝爆炸事故为顶事件,采用布尔代数运算法则求解,得到8个最小割集,通过比较结构重要度得出控制系统失效和液氧排放不连续这两个基本事件的重要度最大,即控制系统失效和液氧排放不连续在故障树结构中对顶事件发生的影响程度最大。因此,为了防止主冷爆炸的发生,要连续排放一定量的液氧,且控制系统监控的准确性也是非常重要的。
Based on the method of fault tree analysis, combined with a large number of accidents at home and abroad, taking the air-to-main condensate explosion as the top event and using Boolean algebraic algorithm to solve the problem, eight minimal cut sets are obtained. By comparing the structural importance, the control system The two fundamental events of failure and liquid oxygen discharge discontinuity are the most important, that is, the control system failure and the discontinuity of liquid oxygen and oxygen discharge have the greatest influence on the top event in the fault tree structure. Therefore, in order to prevent the occurrence of the primary cold blast, a certain amount of liquid oxygen should be continuously discharged and the accuracy of the control system monitoring is also very important.