In vivo mice brain microcirculation monitoring based on contrast-enhanced SD-OCT

来源 :JournalofInnovativeOpticalHealthSciences | 被引量 : 0次 | 上传用户:wulizhu11
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
In this paper, we proposed a contrast-enhanced homemade spectral domain optical coherence tomography (SD-OCT) method for monitoring of brain microcirculation. We used the polyethylene glycol (PEG)-ylated gold nanorods (GNRs) as a contrast-enhanced agent, obtained clearly 2D and 3D OCT images of blood vessels and dynamic changes of probes in mouse blood vessels. Owing to high scattering of the PEG-GNRs, more tiny blood vessels can be imaged and the OCT signal can be enhanced by 5.87 dB after injection of PEG-GNRs for 20 min, the enhancement then declined gradually for 60 min. Our results demonstrate an effective technique for the enhanced imaging of blood vessels in vivo, especially for studies of the brain microcirculation, which could be serviced for disease mechanism research and therapeutic drug monitoring.
其他文献
世界上第一台运转的自由电子激光器,斯坦福大学超导自由电子激光器的最新变型,通过电子束两次循环经过直线加速器,使它从电子提取的能量较原来增加一倍左右,取得了另一次突破。
期刊
针对传统定时同步算法的副峰干扰和低信噪比(SNR)下定时不稳定的问题,提出了一种基于伪随机噪声(PN)序列的定时同步算法。根据PN序列良好的延迟相关性和对称相关性,重新设计了训练序列的结构,并优化了定时度量函数的计算方法。仿真结果表明,改进算法的定时度量估计曲线只存在一个峰值,消除了副峰干扰。在循环前缀为四分之一符号长度与低SNR的情况下,仍可实现准确和稳定的定时。
锶原子单态和三重态间的互组跃迁(5s2)1S0-(5s5p)3P1辐射率远小于一般的电偶极跃迁,共振跃迁荧光信号微弱。介绍了一种应用于探测该互组跃迁荧光谱的直流偏置探测器。该探测器选用极低输入偏置电流运算放大器作为前置放大,具有信噪比高、增益高、偏置可调等优点。此探测器探测增益为106 V/W量级,-3 dB带宽为1 MHz。实验中利用该探测器对锶原子互组跃迁(5s2)1S0-(5s5p)3P1微弱共振荧光进行探测,获得信噪比很好的共振荧光谱,且无直流偏置,并由此获得高信噪比的鉴频曲线。应用该探测器观测到
法国通用电气公司马科西研究所的工程师们业已找到了一条大大延长紫外气体激光器寿命的途径,并还可使其效率提高一倍。这一改进有助于实现大功率紫外激光器在半导体生产中的作用,使亚微米平版印刷和整块晶片的单程精确退火成为可能。
期刊
本文对隐花菁Q开关红宝石器件中染料温度、溶剂、杂质含量对于器件动态输出大小的影响进行了理论分析和数值模拟.结果表明,温度、溶剂、杂质效应的基本原因在于染料激发态的吸收,而其中S1→S2的跃迁是主要的.隐花菁的光学漂白程度主要决定于S1→S2的吸收饱和,同时也受到三重态的调节.因此,隐花菁调Q红宝石器件热稳定的主要控制因子是溶剂对染料单态激发态的猝灭速率.
期刊
高能X射线组合透镜是一种基于折射效应的新型X射线光学元件。报道了这种新型X射线光学元件聚焦性能 的最新实验结果。设计的高能X射线组合透镜为聚甲基丙烯酸甲酯(PMMA)材料,包括40个相同的、顺序排布的平凹折射单元,折射单元的球面半径为200 μm,组合透镜的几何口径约为500 μm,长度约为8 mm,焦距约为1.3 m。简要描述了PMMA材料X射线组合透镜的制作技术和制作过程。并给出了X射线组合透镜聚焦性能测试实验系统和实验条件。最后给出8 keV单色X射线辐射下,PMMA材料X射线组合透镜的聚焦性能的测
The optical transmittance properties of single-hole arrays and three-hole chain (vertical) arrays with different geometrical parameters were numerically investigated. It was shown that on increasing the vertical distance between the holes in the hole chai
期刊
We propose an effective way to achieve an enhanced optical absorption surface of titanium alloy 7 (Ti7) fabricated by a femtosecond (fs) laser assisted with airflow pressure. The effect of laser scanning speed and laser power on the surfaces’ morphology a
Higher emission rates and controllable emission direction are big concerns when it comes to finding a good single photon source. Recently, surface plasmons are introduced to this application, as they can manipulate and enhance the luminescence of single e
提出并设计了基于侧边抛磨传感臂结构的光纤Mach-Zehnder干涉结构, 并对其温度传感特性进行了研究。通过将两支分光比为50∶50的1×2端口光纤耦合器相对熔接, 构建光纤Mach-Zehnder干涉结构, 采用单模光纤作为干涉结构的参考臂。基于侧面研磨技术在3m长纤芯/包层尺寸为9/125μm的单模光纤上进行抛光, 抛光时长为5h, 制备了研磨长度为20mm、深度为50μm的光泄露窗作为干涉结构的传感臂, 提高传感器的灵敏度。采用宽带光源对Mach-Zehnder干涉结构的透射光谱进行测试, 干涉周