论文部分内容阅读
比较标准草案和《美国药典》恩替卡韦有关物质的测定方法,确定恩替卡韦有关物质的测定方法.采用Welch uLtimate AQ-C18柱(4.6 nm×250 mm,5μm),体积流量为1.0 mL/min,柱温为30℃,检测波长为254 nm.标准草案以水-乙腈-5%三氟乙酸(95:5:0.05)为流动相A、乙腈为流动相B,进行梯度洗脱;《美国药典》以水-乙腈(97∶3)为流动相A、乙腈为流动相B,进行梯度洗脱.均采用自身对照法测定.两种方法中非对映异构体RRS、RRR、SRR,8-羟基恩替卡韦和8-羟甲基恩替卡韦分离度均符合要求.标准草案非对映异构体RRS、RRR、SRR回收率分别为98.2%,98.5%和98.6%,RSD%分别为1.4%,1.9%/和1.8%;《美国药典》非对映异构体RRS、RRR、SRR回收率分别为99.8%,98.2%和98.5%,RSD%分别为1.4%,1.7%和1.9%.标准草案灵敏度较高,分析时间较短,可用于恩替卡韦有关物质的测定.“,”To compare draft standard and USP for determination of the related substances in Entecavir,and developing the method for determination of the related substances of Entecavir,separation was carried out on a Welch uLtimate AQ-C1s (4.6 nm× 250 mm,5.0 μm),the flow rate was 1.0 mL/min at a temperature of 30 ℃.The UV detection wavelength was 254 nm.The gradient elution mobile phase consisted of two eluents:water-acetonitrile-5% trifluoroacetic acid (95:5:0.05)as mobile phase A,acetonitrile as mobile phase B in draft standard.The gradient elution mobile phase consisted of two water-eluents:acetonitrile (97:3) as mobile phase A,acetonitrile as mobile phase B in USP.Self standard was used.The resolution of RRS、RRR、SRR、8-Hydroxy Entecavir、8-Methoxy Entecavir and entecavir was good.The recovery of the draft standard was 98.2% (RRS) 、98.5% (RRR) and 98.6% (SRR),RSD% was 1.4% (RRS) 、1.9% (RRR) and 1.8% (SRR).The recovery of USP was 99.8% (RRS) 、98.2% (RRR) and 98.5% (SRR),RSD% was 1.4% 、1.7% and 1.9% o The draft standard is more sensitive and quick.It can be uesd for determination of the related substances in Entecavir.