IN VIVO CHARACTERIZATION OF ATTACHMENT SAFETY BETWEEN CARDIAC PACING LEAD AND CANINE HEART MUSCLE

来源 :Acta Mechanica Solida Sinica | 被引量 : 0次 | 上传用户:chen6524
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
In vivo experiments of screwing the electrode of canine hearts and assigning external excitation on the lead-myocardium interface was carried out to evaluate the lead/myocardium adherence safety.The electrode is specially designed to host a measurement unit of strain gauges. We obtained the lead/heart interactions data from 12 dogs under natural heart beating and beating with external excitations.The data recorded from the acute phase and the chronic phase of pulling out pacing leads were compared with each other.The electrode/heart interaction is caused by the heart beat and influenced by the lung breath.This process induced tolerable damage to the lead or myocardium.The interaction decreases as the frequency of external excitations increases.The lead is more likely to be detached from myocardium under higher excitation frequency.At the same implanting sites,safer pacing lead/myocardium attachment can be realized in the chronic tests than in the acute tests. In vivo experiments of screwing the electrode of canine hearts and assigning external excitation on the lead-myocardium interface was carried out to evaluate the lead / myocardium adherence safety. The electrode is specially designed to host a measurement unit of strain gauges. We obtained the lead / heart interactions data from 12 dogs under natural heart beating and beating with external excitations. The data recorded from the acute phase and the chronic phase of pulling out pacing leads were compared with each other. The electrode / heart interaction is caused by the heart beat and influenced by the lung breath. This process induced tolerable damage to the lead or myocardium. The interaction decreases as the frequency of external excitations increases. The lead is more likely to be detached from the myocardium under higher excitation frequency. At the same implanting sites, safer pacing lead / myocardium attachment can be realized in the chronic tests than in the acute tests.
其他文献
在这篇论文,碰撞本地人时间的存在和光滑为二个独立部分 Brownian 运动被证明,通过 L~2 集中和混乱扩大。而且,碰撞本地人时间过程的整齐被学习。
By modeling metal as a special piezoelectric material with extremely small piezoelectricity and extremely large permittivity, we have obtained the analytical so
Structural parameters of 24 substituted naphthalin compounds were computed at four levels using Hartree-Fock and DFT methods. Based on the experimental data of
Rutile TiO2(001) quantum dots (or nano-marks) in different shapes were used to imitate uncleaved material surfaces or materials with rough surfaces. By numerica
Oleic acid (OA)-modified SiO2 (OA-m-SiO2) nanoparticles were prepared using surface modification method.Infrared spectroscopy (IR) was used to investigate the s
Monodisperse poly(poly(ethyleneglycol) methyl ether acrylate-co-acrylic acid) (poly(PEGMA-co-AA))microspheres were prepared by distillation-precipitation polyme
A novel coordination polymer {[Zn(ts-gln)(bipy)]·3H2O}n (ts-glnH2 = N-p-tolysulfonyl-glutamine, bipy = 2,2-bipyridine) has been prepared and structuraily chara
The selection of the configuration and size of an aerator was of importance for a tunnel spillway under the conditions of high speed flows. Experimental investi
On the basis of analyzing the result of numerical simulation and that of theoretical analysis,the sys tematic error of some air spring s theoretical formula is
Ti-45Al-9(V,Nb,Y) alloys with four different x=V/Nb (atomic ratio x = 1,1.5,2 and 3.5) have been prepared,and the microstructures,properties and hot deformation