论文部分内容阅读
卫生部一九八三年颁布的《注射剂(水针)澄明度检查细则和判断标准》中规定,大型输液的检查方法:即:直立、倒立、平视三步法旋转进行澄明度检查.我们改为:倒立、平视、直立三步法旋转检视,大大降低了灯检的漏检率。因为输液消毒前后一直处于直立状态,第一步就倒立旋转,沉于瓶底的白点、白块、异物,由于重力的作用就呈现出来。第二步采用平视旋转能检出悬浮于溶液中的及部分粘着瓶壁的白点、白块异物。最后按直立旋
Ministry of Health promulgated in 1983, “injection (water needle) Inspection Regulations and Criteria for the determination of”, the large infusion of inspection methods: namely: upright, inverted, head-up three-pronged rotation clarity test. As: inverted, head-up, upright three-step rotating view, greatly reducing the missed light inspection rate. Because before and after infusion disinfection has been in an upright state, the first step on the inverted rotation, sinking at the bottom of the white spots, white, foreign bodies, due to the role of gravity on the show. The second step using head-up rotation can be detected in suspension in the solution and the partial adhesion bottle wall white spots, white foreign body. Finally press the vertical spin