Dynamic Simulation and Performance Investigation of No-frost Refrigerator: Part Ⅰ Mathematical Model

来源 :上海交通大学学报(英文版) | 被引量 : 0次 | 上传用户:liyunfeng890406
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
A dynamic approach for the modeling, simulation and analysis of no-frost Refrigerator (RF) is dis-cussed. In Part Ⅰ, the complex interactions among the components in the cooling system are analyzed in detail, based on which the modeling simplifications are proposed. Then, the mathematical models for the evaporator, cabinet and duct-fan are presented. The whole system is divided into two subsystems-refrigerant cycling system and air cycling system. In order to simplify the model, two closed-loop systems are broken into the compressor component and the evaporator component, respectively. A general distributed parameter model is employed for evaporator with homogeneous flow to simplify the two-phase evaporating flow region. The z-transfer function model is used to describe the cabinet load. Computational fluid dynamics (CFD) method is employed to obtain the pressure drop and flow rate curve of the duct-fan model.
其他文献
The airside heat transfer and friction characteristics of seven interrupted fin-and-tube heat exchangers with hydrophilic coating under dehumidifying conditions are experimented. The effects of number of tube rows, fin pitch and inlet relative humidity on
The experimental system of heat loss of all-glass evacuated solar collector tubes (evacuated tube) is firstly designed and constructed, which uses electric heater as thermal resource. The equilibrium temperatures are less than ±1℃ during the test, and the