论文部分内容阅读
A novel hood structure has been designed for the dust control system in the foundry in order to improve the working environment.A composite strategy has been applied for comparative analysis of the optimal venting volume and the airflow distribution between the conventional hood and the novel one in this study.A Computational Fluid Dynamic (CFD) method is used to simulate the airflow fields and dust-polluted air moving paths.The CFD results show that a two-outlet hood,with one outlet located on the left of the hood,is better for improving dustpolluted air than the hood with one outlet only.It can be concluded that the number of the outlets as well as their location on the hood has a significant influence on the air flow patt in the hood.The optimal venting volume is also a major consideration that is discussed in the study.The venting volume should be designed by considering both the effective level of air flow velocity around the dust source and the energy saving.The optimal airflow distribution may reduce the turbulence in the hood system.