Mini suture anchor: An effective device for reduction and fixation of displaced temporomandibular jo

来源 :中华创伤杂志英文版 | 被引量 : 0次 | 上传用户:kikox3
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Purpose::The main aim is to provide clinical reference for the application of mini suture anchor in the reduction and fixation of displaced temporomandibular joint (TMJ) disc with intracapsular condylar fracture.Methods::From October 2018 to October 2019, 21 patients (31 sides) with intracapsular condylar fractures and articular disc displacement from West China Hospital of Stomatology, Sichuan University were included. The selection criteria were: (1) mandibular condylar fractures accompanied by displacement of the TMJ disc, confirmed by clinical examination, CT scan and other auxiliary examinations; (2) indication for surgical treatment; (3) no surgical contraindications; (4) no previous history of surgery in the operative area; (5) no facial nerve injury before the surgery; (6) informed consent to participate in the research program and (7) complete data. Patients without surgical treatment were excluded. The employed patients were followed up at 1, 3, 6 and 12 months after operation. Outcomes were assessed by success rate of operation, TMJ function and radiological examination results at 3 months after operation. Data were expressed as number and percent and analyzed using SPSS 19.0.Results::All the surgical procedures were completed successfully and all the articular discs were firmly attached to the condyles. The articular disc sufficiently covered the condylar head after the fixation. The fixation remained stable when the mandible was moved in each direction by the surgeons. No complications occurred. The functions of the TMJ were well-recovered postoperatively in most cases. CT scan revealed that the screws were completely embedded in the bone without loosening or displacement.Conclusion::Mini suture anchor can provide satisfactory stabilization for the reduced articular disc and also promote the recovery of TMJ functions.“,”Purpose::The main aim is to provide clinical reference for the application of mini suture anchor in the reduction and fixation of displaced temporomandibular joint (TMJ) disc with intracapsular condylar fracture.Methods::From October 2018 to October 2019, 21 patients (31 sides) with intracapsular condylar fractures and articular disc displacement from West China Hospital of Stomatology, Sichuan University were included. The selection criteria were: (1) mandibular condylar fractures accompanied by displacement of the TMJ disc, confirmed by clinical examination, CT scan and other auxiliary examinations; (2) indication for surgical treatment; (3) no surgical contraindications; (4) no previous history of surgery in the operative area; (5) no facial nerve injury before the surgery; (6) informed consent to participate in the research program and (7) complete data. Patients without surgical treatment were excluded. The employed patients were followed up at 1, 3, 6 and 12 months after operation. Outcomes were assessed by success rate of operation, TMJ function and radiological examination results at 3 months after operation. Data were expressed as number and percent and analyzed using SPSS 19.0.Results::All the surgical procedures were completed successfully and all the articular discs were firmly attached to the condyles. The articular disc sufficiently covered the condylar head after the fixation. The fixation remained stable when the mandible was moved in each direction by the surgeons. No complications occurred. The functions of the TMJ were well-recovered postoperatively in most cases. CT scan revealed that the screws were completely embedded in the bone without loosening or displacement.Conclusion::Mini suture anchor can provide satisfactory stabilization for the reduced articular disc and also promote the recovery of TMJ functions.
其他文献
介绍了某型装备一舱故障诊断处理系统的构成,详细论证了各子系统的功能和工作模式,可为后续该型装备靶试保障及故障定位工作提供技术支撑,也可为后续类似型号的分析工作提供可借鉴的方法和经验.
针对某型直流发电机一起质量问题进行分析,介绍了某型直流发电机的构造,总结了问题产生的原因,分析了现行的修理工艺,提出了使用维护和修理中应采取的措施和改进建议,以确保该型直流发电机在外场的使用安全.
Prosthetic infection is one of the severe postoperative complications of arthroplasty. Mixed bacterial-fungal prosthetic infection is rare but can be disastrous. This case was a 76-year-old female suffered from prosthetic infection following total hip rep
Wide-awake local anesthesia has many advantages. We describe a new method to use wide-awake local anesthesia with more flexibility. A 32-year-old man with a severe right-hand contracture after an iatrogenic tourniquet accident during an anterolateral thig
Schatzkter type-I tibial plateau fracture is a split fracture of the lateral tibial plateau in sagittal plane, consequent to valgus impaction caused by low velocity of trauma. However, a deep understanding of the different columns of the tibial plateau an
Purpose::To investigate the clinical value of urine interleukin-18 (IL-8), neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1) for the early diagnosis of acute kidney injury (AKI) in patients with ureteroscopic lithotrip
Sepsis is a life-threatening clinical syndrome and one of the most challenging health problems in the world. Pathologically, sepsis and septic shock are caused by a dysregulated host immune response to infection, which can eventually lead to multiple orga
Chronic wounds have always been a tough fight in clinical practice, which can not only make patients suffer from pain physically and mentally but also impose a heavy burden on the society. More than one factor is relevant to each step of the development o
Purpose::To retrospectively analyze the clinical outcomes of meniscus repair with simultaneous anterior cruciate ligament (ACL) reconstruction and explore the causes of failure of meniscus repair.Methods::From May 2013 to July 2018, the clinical data of 1