某医院放射防护基本情况调查

来源 :中国辐射卫生 | 被引量 : 0次 | 上传用户:leilei2740
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的为了解某医院放射卫生防护情况。方法 2012年对某医院螺旋CT、多功能DR、高频胃肠机等X射线装置进行了监测并对该单位12名放射工作人员进行了个人剂量监测。结果机房周围环境监测显示为(0.06~0.18)μGy/h,放射工作人员个人剂量监测显示为(0.69~1.3)mSv。结论该医院机房周围环境监测屏蔽安全防护性能基本符合GB18871-2002的要求,该医院个人剂量监测符合GBZ 128-2002的要求。 Purpose To understand the radiation protection situation in a hospital. Methods In 2012, a X-ray device of a spiral CT, multi-function DR, high-frequency gastrointestinal machine in a hospital was monitored and 12 individual radiation workers in the unit were monitored for their personal dosages. Results The environmental monitoring of the engine room showed (0.06 ~ 0.18) μGy / h, and the personal dose monitoring of radiation workers showed (0.69 ~ 1.3) mSv. Conclusion The safety performance of the environment monitoring shield around the hospital room basically meets the requirements of GB18871-2002. The personal dose monitoring of this hospital meets the requirements of GBZ 128-2002.
其他文献
请下载后查看,本文暂不支持在线获取查看简介。 Please download to view, this article does not support online access to view profile.
本文主要针对影响氧化锆分析仪平稳运行的原因及解决措施展开深入研究,重点通过一催化氧化锆锆头过滤网堵塞、老区二催化氧化锆过滤器堵塞故障率较高、氧化锆部分安装位置在
目的 通过研究2 Gyγ射线离体和全身照后12 h大鼠外周血淋巴细胞差异基因表达谱的变化情况,在分子水平上为辐射损伤机制的研究提供依据.方法 利用基因芯片技术对大鼠离体和全
目的 探讨常规头部CT采用管电流自动调节技术(即TCM螺旋扫描模式)能否降低照射剂量和提高影像质量.方法 50例成人患者,分别接受常规头部CT的TCM螺旋和常规轴扫模式,常规轴扫
目前,我国建筑用能浪费极其严重,而且建筑能耗增长的速度远远超过我国能源生产可能增长的速度,如果听任这种高耗能建筑持续发展下去,国家的能源生产势必难以长期支撑此种浪费
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
目的对商丘市医疗机构的放射卫生监督状况进行调查分析,掌握医疗机构的放射防护情况。方法于2011年至2012年期间对市内22家医疗机构进行现场调查,采用现场检测和问卷调查的方
目的通过2011年全国放射工作人员个人剂量监测系统比对活动,检验本实验室个人剂量监测能力。方法按照《全国放射工作人员个人剂量监测系统比对方案》的要求,将多组常规监测用
随着社会的进步,城市高楼林立,楼层越来越高,深基坑工程数量急剧增加,技术上也有了很大的进步.大量的工程实践积累了丰富的深基坑工程设计施工经验,但随着城市建设的发展,关
目的为加强放射防护工作,通过对放射工作人员外照射的个人剂量进行调查,进而了解不同类型医院和不同工种的外照射年剂量当量和人均年剂量当量的差别。方法依据湛江市卫生监督