,Accuracy of left ventricular function from electrocardiography-gated myocardial perfusion SPECT by

来源 :核技术(英文版) | 被引量 : 0次 | 上传用户:ttklwoyaosha
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
This work was to determine threshold values for accurate measurements of left ventricular end-diastolic volume (EDV),end-systolic volume (ESV),and ejection fraction (EF) from electrocardiography-gated myocardial perfusion imaging (MPI) in Chinese,and these data were compared with those of echocardiography.A total of 110 patients with definite or suspected coronary artery disease were referred for both gated MPI and echocardiography within 1 week.The EDV,ESV,and EF automatically measured by MyoMetrix and echocardiography were analyzed using Bland-Altman plot correlation and paired t test.The results showed that these parameters quantified by MyoMetrix software were correlated,moderately to highly,with those on echocardiography (ρ,r ≥ 0.75,P < 0.01).However,the EF was not significantly correlated,with post-exercise MPI ESV of <15 mL or resting MPI ESV of <20 mL.At or above this ESV value,EF was underestimated by MyoMetrix (t ≥ 4.60,P < 0.01).In a word,a small ESV was underestimated by MyoMetrix,which could lead to EF overestimation.On the contrary,a normal or large ESV was overestimated by MyoMetrix,which led to EF underestimation.
其他文献
As a robust platform for genome editing,CRISPR/Cas9 is currently being explored for engineering biology or therapeutics,yet means for quantitative detection of
本文分析了酒泉大规模风电接入后,风电功率波动时不同串补和高抗配置方案下各750kV变电站以及汇集风电的330kV变电站的低压无功补偿设备的投切情况。 This paper analyzes t
Conventional X-ray tube-based cone-beam computed tomography(CX-CBCT) systems have great potential in industrial applications. Such systems can rapidly obtain a three-dimensional(3D) image of an object
Identification of nuclear pulse signal is of importance in radioactive measurements,especially in recognizing adjacent overlapping nuclear pulses.In this articl
In this study,a high-throughput screening method was established through the 24-square deep-well microliter plate (MTP) fermentation and micro-plate detection f
Knowledge of actinides(n,f) fission process induced by neutron is of importance in the field of nuclear power and nuclear engineering,especially for reactor app
The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ra
We predict proton single event effect (SEE) error rates for the VATA160 ASIC chip on the Dark Matter Particle Explorer (DAMPE) to evaluate its radiation toleran
本文介绍了EPS的工作原理,还详细分析了EPS的构造和工作原理以及带负载时的工作特性和运行参数.